Credits issued1,000Y+

6.41 tCO₂e removal by Vaulted Deep

rmv_1JPJQT6RZ1S0MV97

Removal details

Supplier
Tonnes removed
6.41 tCO₂e
Sequestration date
10 Mar 2025
Reporting period
11 Feb 2025 to 10 Mar 2025

Verification details

Version
v1.1
Verifier

Data points (42)

NameValueCollection methodSources
Attribution factor1.000000 Reported
Mass of waste biomass23.678 tReportedMass of waste biomass
CO2e eq mass of C3.666667 Constant
Attribution factor1.000000 Reported
Front loader diesel consumption13 kgReported
Carbon intensity of combustion4.05 kgCO₂e/kgStandard Published Value
Attribution factor1.000000 Reported
Screening Time1 kgDerived
Trommel Carbon intensity of combustion18.77 kgCO₂e/kgStandard Published Value
Attribution factor1.000000 Reported
Screening Front loader diesel consumption5 kgReported
Attribution factor1.000000 Reported
Biomass transport distance85.30 kmReportedDistance from feedstock source to processing site
Diesel emissions factor3,442.99 kg/m³Standard Published Value
Empty truck MPG6.00 mi/galStandard Published Value
Attribution factor1.000000 Reported
Fully loaded truck MPG5.00 mi/galStandard Published Value
Attribution factor1.000000 Reported
Mass of lab samples0 kgDerived
Distance to lab490.85 kmStandard Published Value
lab sampling truck emissions factor0.24 kgCO₂e/km/tStandard Published Value
Attribution factor0.000012 Standard Published Value
Volume of concrete used in facility367.428 tDerived
Concrete emissions factor152.73 kgCO₂e/tStandard Published Value
Attribution factor1.000000 Reported
Processing & Injection energy use180.00 kWhReportedProcessing & Injection energy use
Pump embodied emissions factor0.01 kgCO₂e/MJStandard Published Value
Mass of steel used in facility100.369 tDerivedMass Steel Mp2 Horizontal Ginder
Steel production emissions factor5.13 kgCO₂e/kgStandard Published Value
Steel scrapping emissions factor0.01 kgCO₂e/kgStandard Published Value
Attribution factor1.000000 Reported
Office Energy Consumption11.50 kWhDerivedOffice Energy Consumption
Grid emissions factor0.52 kgCO₂e/kWhStandard Published Value
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Replacement Emission0.00 kgCO₂e/tStandard Published ValueReplacement Emission
Estimated carbon content of injectantMultiple values 288 measurements