Credits issued1,000Y+
6.31 tCO₂e removal by Vaulted Deep
Removal details
Supplier
Tonnes removed
6.31 tCO₂e
Sequestration date
10 Mar 2025
Reporting period
11 Feb 2025 to 10 Mar 2025
Removal method
Calculation view
Datapoints
| Name | Value | Collection method | Sources |
|---|---|---|---|
| Mass of waste biomass | 23.442 t | Reported | Mass of waste biomass |
| CO2e eq mass of C | 3.666667 | Constant | — |
| Mass of lab samples | 0 kg | Derived | — |
| Distance to lab | 490.85 km | Standard Published Value | — |
| lab sampling truck emissions factor | 0.24 kgCO₂e/(km⋅t) | Standard Published Value | — |
| Attribution factor | <0.01% | Standard Published Value | — |
| Volume of concrete used in facility | 367.428 t | Derived | — |
| Concrete emissions factor | 152.73 kgCO₂e/t | Standard Published Value | — |
| Processing & Injection energy use | 260.00 kWh | Reported | Processing & Injection energy use |
| Pump embodied emissions factor | 0.01 kgCO₂e/MJ | Standard Published Value | — |
| Mass of steel used in facility | 100.369 t | Derived | Mass Steel Mp2 Horizontal Ginder |
| Steel production emissions factor | 5.13 kgCO₂e/kg | Standard Published Value | — |
| Steel scrapping emissions factor | 0.01 kgCO₂e/kg | Standard Published Value | — |
| Office Energy Consumption | 13.50 kWh | Derived | Office Energy Consumption |
| Grid emissions factor | 0.52 kgCO₂e/kWh | Standard Published Value | — |
| Front loader diesel consumption | 19 kg | Reported | — |
| Carbon intensity of combustion | 4.05 kgCO₂e/kg | Standard Published Value | — |
| Screening Time | 1 kg | Derived | — |
| Trommel Carbon intensity of combustion | 18.77 kgCO₂e/kg | Standard Published Value | — |
| Screening Front loader diesel consumption | 5 kg | Reported | — |
| Biomass transport distance | 85.30 km | Reported | Distance from feedstock source to processing site |
| Diesel emissions factor | 3,442.99 kg/m³ | Standard Published Value | — |
| Empty truck MPG | 7.00 mi/gal | Standard Published Value | — |
| Fully loaded truck MPG | 6.00 mi/gal | Standard Published Value | — |
| Replacement Emission | 0 kgCO₂e/t | Standard Published Value | Replacement Emission |
| Estimated carbon content of injectant | Multiple values | — | 288 measurements |