Credits issued1,000Y+

2.31 tCO₂e removal by Vaulted Deep

rmv_1JVDMCNW91S09RZ1

Removal details

Supplier
Tonnes removed
2.31 tCO₂e
Sequestration date
09 May 2025 to 10 May 2025
Reporting period
11 Apr 2025 to 11 May 2025

Verification details

Version
v1.1
Verifier

Data points (38)

NameValueCollection methodSources
Attribution factor1.000000 Reported
Mass of waste biomass12.646 tReportedMass of waste biomass
CO2e eq mass of C3.666667 Constant
Attribution factor1.000000 Reported
Front loader diesel consumption15 kgReported
Carbon intensity of combustion4.05 kgCO₂e/kgStandard Published Value
Attribution factor1.000000 Reported
Biomass transport distance59.55 kmReportedBiomass transport distance
Diesel emissions factor3,442.99 kg/m³Standard Published Value
Empty truck MPG5.20 mi/galStandard Published Value
Attribution factor1.000000 Reported
Fully loaded truck MPG4.00 mi/galStandard Published Value
Attribution factor1.000000 Reported
Mass of lab samples1 kgDerivedMass of lab samples
Distance to lab490.85 kmStandard Published Value
lab sampling truck emissions factor0.24 kgCO₂e/(km⋅t)Standard Published Value
Attribution factor0.000006 Standard Published Value
Volume of concrete used in facility367.428 tDerived
Concrete emissions factor152.73 kgCO₂e/tStandard Published Value
Attribution factor1.000000 Reported
Processing & Injection energy use100.00 kWhReportedProcessing & Injection energy use
Pump embodied emissions factor0.01 kgCO₂e/MJStandard Published Value
Mass of steel used in facility290.930 tDerivedMass of steel used in facility
Steel production emissions factor5.13 kgCO₂e/kgStandard Published Value
Steel scrapping emissions factor0.01 kgCO₂e/kgStandard Published Value
Attribution factor1.000000 Reported
Office Energy Consumption6.00 kWhDerivedOffice Energy Consumption
Grid emissions factor0.52 kgCO₂e/kWhStandard Published Value
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Attribution factor1.000000 Reported
Replacement Emission0.00 kgCO₂e/tStandard Published ValueReplacement Emission