Credits issued1,000Y+
2.31 tCO₂e removal by Vaulted Deep
Removal details
Supplier
Tonnes removed
2.31 tCO₂e
Sequestration date
09 May 2025 to 10 May 2025
Reporting period
11 Apr 2025 to 11 May 2025
Removal method
Calculation view
Data points
Data points (38)
Name | Value | Collection method | Sources |
---|---|---|---|
Attribution factor | 1.000000 | Reported | — |
Mass of waste biomass | 12.646 t | Reported | Mass of waste biomass |
CO2e eq mass of C | 3.666667 | Constant | — |
Attribution factor | 1.000000 | Reported | — |
Front loader diesel consumption | 15 kg | Reported | — |
Carbon intensity of combustion | 4.05 kgCO₂e/kg | Standard Published Value | — |
Attribution factor | 1.000000 | Reported | — |
Biomass transport distance | 59.55 km | Reported | Biomass transport distance |
Diesel emissions factor | 3,442.99 kg/m³ | Standard Published Value | — |
Empty truck MPG | 5.20 mi/gal | Standard Published Value | — |
Attribution factor | 1.000000 | Reported | — |
Fully loaded truck MPG | 4.00 mi/gal | Standard Published Value | — |
Attribution factor | 1.000000 | Reported | — |
Mass of lab samples | 1 kg | Derived | Mass of lab samples |
Distance to lab | 490.85 km | Standard Published Value | — |
lab sampling truck emissions factor | 0.24 kgCO₂e/(km⋅t) | Standard Published Value | — |
Attribution factor | 0.000006 | Standard Published Value | — |
Volume of concrete used in facility | 367.428 t | Derived | — |
Concrete emissions factor | 152.73 kgCO₂e/t | Standard Published Value | — |
Attribution factor | 1.000000 | Reported | — |
Processing & Injection energy use | 100.00 kWh | Reported | Processing & Injection energy use |
Pump embodied emissions factor | 0.01 kgCO₂e/MJ | Standard Published Value | — |
Mass of steel used in facility | 290.930 t | Derived | Mass of steel used in facility |
Steel production emissions factor | 5.13 kgCO₂e/kg | Standard Published Value | — |
Steel scrapping emissions factor | 0.01 kgCO₂e/kg | Standard Published Value | — |
Attribution factor | 1.000000 | Reported | — |
Office Energy Consumption | 6.00 kWh | Derived | Office Energy Consumption |
Grid emissions factor | 0.52 kgCO₂e/kWh | Standard Published Value | — |
Attribution factor | 1.000000 | Reported | — |
Attribution factor | 1.000000 | Reported | — |
Attribution factor | 1.000000 | Reported | — |
Attribution factor | 1.000000 | Reported | — |
Attribution factor | 1.000000 | Reported | — |
Attribution factor | 1.000000 | Reported | — |
Attribution factor | 1.000000 | Reported | — |
Replacement Emission | 0.00 kgCO₂e/t | Standard Published Value | Replacement Emission |
Carbon content measurements of injectant | Multiple values | — | 3 measurements |
Historical carbon content measurements of injectant | Multiple values | — | 84 measurements |