This Protocol sets the specific requirements under which Environmental Attribute Certificates (EACs) are issued for low-carbon clinker, cement, and concrete.
Cement and concrete account for approximately 8 percent of global greenhouse gas (GHG)emissions, and many of the technologies needed to decarbonize the sector at scale, including carbon capture, utilization and storage (CCUS), novelNovel binderBinders, and kiln electrification, remain capital-intensive and early in deployment. Book and claim decouples environmental attributes from physical delivery, allowing demand to reach production sites regardless of geography and channeling investment into decarbonization at the point where emissions arise.
This Protocol is the clinker, cement and concrete-specific methodology layer of Isometric's EAC infrastructure. It operates under the Isometric Standard, which sets the cross-cutting requirements for EAC issuance, ownership, transfer, and lifecycle. This Protocol sets the requirements for eligibility, calculation methodology, integrity safeguards, and Certificate Attributes. Downstream claims made by Beneficiaries are governed by the relevant Buyer reporting frameworks.
Specific standards and Protocols which are utilized as the foundation of this Protocol and forwith which this Protocol is intended to be fully compliant with are as follows:
The Protocol also draws on the following Isometric Modules and Protocols, reference frameworks, and Buyer reporting standards:
The Protocol also references the following secondary technical standards, product standards, and regulations:
This Protocol was developed based on the current state of cement decarbonization technology, the Buyer reporting frameworks and the reference frameworks published as of its release. Book and claim for cement and concrete is a developing market mechanism, and the frameworks this Protocol aligns with are themselves evolving. For example, the SBTi Corporate Net-Zero Standard V2.0 takes effect on February 1, 2027 and the GHG Protocol is developing a standard for Market Instruments.
The Protocol will be updated periodically in line with advancements in the available technology, the published frameworks, and market practice.
The Protocol recognizes three Functional Units: one metric tonne of clinker, one metric tonne of cement, or one cubic meter of concrete1. EAC quantities issued, transferred, and retired on the Registry are recorded in these units. An EAC represents the Carbon Intensity of the product per Functional Unit. Certificate Attributes, including the Baseline value, Baseline type, and Emission Reduction Value, are carried alongside it, per Appendix D.
Clinker, cement, and concrete are distinct products, each with theirits own Baseline and its own emissions intensity threshold, and a separate EAC is issued against each Functional Unit. Product standards and Environmental Product Declaration (EPD) sourcing per Functional Unit are set in Section 7.1. No standalone clinker PCR exists, so a clinker EAC's EPD is prepared under the applicable cement Product Category Rule (PCR) at a 100 percent clinker ratio.
An EAC is issued against one Functional Unit and remains at that Functional Unit and no conversion route is available, per Section 11.2. Where the verified EPD reports Carbon Intensity in a different declared unit, Thethe Project Proponent must convert the reported value to the applicable Functional Unit before issuance, and the conversion is confirmed by Isometric at Issuance Review.
Cement and concrete EACs are denominated in their own Functional Units, not in clinker-equivalent units. The conversion ratios between the three Functional Units vary widely, and that variation is itself driven by the decarbonization levers this Protocol certifies. Clinker-equivalent translation tables are provided separately, for Buyer estimation only, per Appendix C.
A standalone Supplementary Cementitious Material (SCM) Functional Unit is not adopted in this version of the Protocol. An SCM may be certified at the cement or concrete Functional Unit, per Section 7.2.2, and an SCM producer may be Thethe Project Proponent and hold the EAC for that unit, per Section 5.4. Certifying an SCM functionalFunctional unitUnit depends on methods that are still developing, in particular a consistent and assurable way to establish an SCM replacement rate, which no current standard yet provides2. Isometric will review inclusion of SCMs as a Functional Unit in periodic updates to this Protocol per Section 3, once a recognized method for cement-unitized SCM replacement rates is published and in line with industry standards.
The Book and Claim Boundary under this Protocol is as follows:
Section 12 provides non-binding guidance on how EACs issued under this Protocol can be applied under relevant Buyer frameworks.
For each Project to be evaluated under this Protocol, Thethe Project Proponent must document Project characteristics in a Project Design Document (PDD) as outlined in the Documentation section of the Isometric Standard. The PDD will form the basis for Project Validation and evaluation in accordance with this Protocol, and must include consideration of items specific to clinker, cement, and concrete EAC Projects:
Projects must be Validated by a Validation and Verification Body (VVB) selected and engaged by Isometric and are subject to annual Surveillance Audits, consistent with Section 4 of the Isometric Standard. At each Surveillance Audit and at re-validationValidation, the VVB reviews a representative sample of the issuance requests made since the previous audit and confirms their conformity with the Validated scope of the Project and this Protocol. This section sets out the cement, concrete and clinker-specific requirements that apply in addition to that framework.
The VVB must maintain team expertise in the decarbonization pathway certified under this Protocol. The materiality threshold applied at Validation and each Surveillance Audit is that of the applicable PCR, per Section 8.2. Qualitative materiality issues, including control weaknesses, poorly managed documentation, and regulatory noncompliance indirectly related to greenhouse gas emissions, must additionally be identified and documented.
Each EAC issuance request is subject to an Issuance Review carried out by Isometric, per Section 4.2.3 of the Isometric Standard. An Issuance Review does not require a VVB.
The EPD that carries the Project's certified Carbon Intensity is separately verified under ISO/IEC 17029 for the applicable PCR. The verification requirements for the EPD, including the verification routes required where the certified product relies on CCUS, are set in Section 8.2.
The ownership requirements of Section 3.1 of the Isometric Standard apply to Projects certified under this Protocol. A single Project Proponent must be specified as the sole owner of the Environmental Attributes represented by each EAC issued under this Protocol.
A party other than Thethe Project Proponent is a Project participant where the Project depends on data or evidence from that party, or where that party could otherwise claim the emissions performance of the input it supplies. The Project Proponent must hold a contract with each Project participant meeting the requirements of Section 3.1 of the Isometric Standard, and must identify each Project participant and its role in the PDD. A party that supplies an input on arm's length terms is not a Project participant where it does not market that input on the basis of its emissions performance and the input's Carbon Intensity enters the verified EPD as a published or secondary dataset value.
For Projects certified under this Protocol, this test applies to the parties commonly involved in a cement value chain, for example:
Additionality asks whether a Project's decarbonization goes beyond what would have happened without EAC revenue. Buyer-side frameworks approach this differently. Rather than fix a single Additionality bar, this Protocol reports Project-level information against each pillar so Buyers can apply whichever bar their own framework or claim requires.
Catalytic Impact, being whether a Project meaningfully advances the sector's decarbonization frontier, is a separate concept and is addressed through the mandatory Catalytic Impact narrative in Section 7.4. The four pillars of Additionality are assessed as follows.
Environmental Additionality asks whether the certified reduction is real, measurable, and below a Baseline. Under this Protocol it is satisfied by the eligibility criteria and requires no separate test. A Project must carry a verified EPD (Section 7.1) and meet the emissions intensity threshold outlined in Section 7.3.
Common Practice Additionality asks whether the decarbonization activity is already widespread in the sector. The assessment is folded into the following two mechanisms:
Financial Additionality asks whether EAC revenue is necessary to enable the decarbonization decision. The counterfactual is a conventional facility, not the absence of a facility, so the question is whether EAC revenue closes the remaining viability gap for the decarbonization decision specifically.
Under this Protocol, Financial Additionality is not separately tested at Issuance4. The following mechanisms together screen out Projects whose decarbonization would have occurred without EAC revenue: the emissions intensity threshold in Section 7.3, which excludes production above the applicable GCCA Low-Carbon Ratings band and so screens out business-as-usual output; the exclusion of traditional SCMs in Section 7.2.2; and the Regulatory Surplus criterion in Section 5.5.4.
A Project Proponent may optionally select an enhanced pathway, in which Financial Additionality is demonstrated through the full Project financials and Internal Rate of Return analysis set out in the Financial Additionality section of the Isometric Standard. The IRR analysis must reflect all cement-specific components of the Project's economics, including:
[/R-DE07-0]Sensitivity analysis must vary energy prices, feedstock and reagent prices, emissions trading system allowance prices where applicable, and the expected EAC price, in accordance with the ±20 percent floor in the Isometric Standard.
An EAC issued under this pathway carries the Enhanced Financial Additionality Declaration label on the Registry. The VVB confirms the IRR analysis at Validation and reassesses at each Surveillance Audit, and in particular where Thethe Project Proponent's position on any of the government subsidies, tax credits, emissions trading system allowances, or primary decarbonization input costs changes materially over the Crediting Period.
Regulatory Additionality asks whether the certified reduction goes beyond what regulation already requires, and whether the same reduction has been used to meet a compliance obligation. The activity may be legally required regardless of EAC revenue, in which case the reduction would have happened anyway, or the reduction may have been surrendered against a compliance obligation, in which case counting it again would count it twice.
This Protocol addresses both through a single Regulatory Surplus test, applied to every EAC issued under this Protocol, using the definition in Section 5.6 and the process set out in Appendix G of the AIM Platform Standard V1.05. Regulatory Surplus is tested at the entity and immediate supply chain level. System-level allowance dynamics under cap-and-trade programs are not addressed. Where the AIM Platform Standard is updated, this Protocol is reviewed and, where required, updated at the next version release, per Section 3.
The Project Proponent must declare a Regulatory category from the four classes and provide the required Regulatory Surplus Evidence, as set out in Table 1.
[/R-12VW-0]Table 1. Regulatory categories
Category | Definition | Regulatory Surplus Evidence |
|---|---|---|
Policy Free | The producer is not obligated by any policy, and has not received government incentives, to decarbonize the product. | [G-525A-0, Projects declaring the Policy Free category must attest that the intervention activity is not required by any regulatory program applicable to the producer or to an entity in the producer's immediate supply chain.] The Project Proponent must attest that the intervention activity is not required by any regulatory program applicable to the producer or to an entity in the producer's immediate supply chain. [/G-525A-0] |
Incentive Supported | The producer or an upstream product has received government incentives that support the lower emissions intensity carried on the EAC. | [G-RQ0Z-0, Projects declaring the Incentive Supported category must identify each incentive program received (incentive category and awarding body), and for market-based certificate trading systems in which the producer is a regulated party must additionally attest that the generated certificate has not and will not be used for the producer's own compliance or transferred for another party's compliance.] For voluntary incentive programs, Regulatory Surplus is demonstrated by the incentive itself. The Project Proponent must identify each incentive program received, disclosing the incentive category and the awarding body. For market-based certificate trading systems with a defined emissions threshold under which the producer is a regulated party, |
Mandated Action | The producer or an upstream product is obligated to reduce emissions through specified actions, or to produce or procure materials with characteristics tied to the EAC. Relevant regulations include facility-level emission caps, product emissions-intensity limits, and production requirements tied to environmental attributes. | [G-CBWM-0, Projects declaring the Mandated Action category must identify the specific applicable regulatory program and attest that the intervention outcomes represent reductions beyond what that program requires, or have been withheld from compliance use, with reference to the producer's compliance filings for the Reporting Period.] The Project Proponent must (i) identify the specific regulatory program applicable to the certified reduction, and (ii) attest that the intervention outcomes represent emission reductions beyond what that program requires, or have been withheld to prevent them from being used for compliance under that program. The producer's compliance filings for the Reporting Period must be referenced. [/G-CBWM-0] |
Cap-and-Trade Coverage | The producer or an upstream product is regulated under a market-based system that mandates emissions outcomes across all regulated parties without requiring specific actions by any individual entity. Relevant regulations include emissions trading systems and economy-wide caps. | [G-00R9-0, Projects declaring the Cap-and-Trade Coverage category must identify the applicable cap-and-trade system(s), name the entity that implemented the intervention, and attest that this entity is a regulated party under that system.] The Project Proponent must identify the applicable cap-and-trade system(s), name the entity that implemented the intervention, being either the producer or an entity in the producer's immediate supply chain, and attest that this entity is a regulated party under that cap-and-trade system. [/G-00R9-0] |
The Regulatory category and the Regulatory Surplus Evidence are recorded on the EAC, publicly visible on the Registry, and confirmed by the VVB at Validation and at each Surveillance Audit.
Section 3.7.2 of the Isometric Standard provides that the Uncertainty in the Carbon Intensity of an EAC is inherited from the certification of the underlying product, as set by the relevant Protocol.
For this Protocol, the underlying certification is the verified EPD and the applicable PCR under which it is prepared (Section 8). The PCR sets the data quality requirements, materiality threshold, and sensitivity analysis approach that govern the reported value. Where the PCR is silent, the corresponding provisions of ISO 21930 or EN 15804 apply.
The Carbon Intensity is carried on the EAC as declared on the verified EPD, except for open-system storage pathways, where an uncertainty discount for reversal risk is applied to the stored CO₂ per Section 9.2.1. No other uncertainty discount is applied to the Carbon Intensity figure.
The Baseline is a fixed reference value, such as a pre-intervention EPD, an approved regional benchmark or a GCCA Low-Carbon Ratings band, and does not have an uncertainty discount applied. The Baseline type, value, source and vintage are carried as Certificate Attributes per Appendix D, so that Buyers can assess any emissions reduction claim against the requirements of their own reporting framework.
In accordance with Section 3.12 of the Isometric Standard, all evidence and data related to EAC issuance under this Protocol will be publicly available through the Isometric Registry. This includes the following:
The Project Proponent may request certain information to be restricted, available only to authorized buyers, the Registry, and the VVB, where the information is subject to confidentiality. That restriction does not apply to any numerical data used to quantify the Carbon Intensity, the Emission Reduction Value, or the stored CO₂ issued within a CCUS-backed EAC.
A clinker, cement, or concrete EAC Project must consider the material environmental and social impacts that could arise from its activities, both within and beyond its Project boundary, and must demonstrate no net environmental or social harm. The overarching requirements are set out in the Environmental and Social Impacts section of the Isometric Standard. This section states the specific requirements that apply above those baseline obligations. Compliance with this section will be assessed by the VVB at initial Validation and at each annual Surveillance Audit.
The following requirements apply and must be addressed explicitly in the PDD, in addition to the general risk identification required in the Isometric Standard.
The storage operator is typically a separate legal entity from the cement producer. The PDD must identify which party is responsible for each CCUS-related safeguarding obligation and must demonstrate that responsibilities are contractually allocated for the full duration of storage monitoring, including post-handover obligations per Section 9.7 of this Protocol.
[/G-9JSW-0]Environmental and social safeguarding data generated under this section must be made publicly available through the Isometric Registry. The Project Proponent may request that specific data be restricted where confidentiality concerns apply, subject to the data restriction rules in the Isometric Standard.
This section sets out the eligibility requirements for EAC issuance under this Protocol. A Project must meet the following requirements: the EPD and PCR requirements in Section 7.1, the pathway and exclusion rules in Section 7.2, and the emissions intensity threshold in Section 7.3. In addition, Thethe Project Proponent must submit a Catalytic Impact narrative under Section 7.4, which is a mandatory disclosure for Buyers to assess against their own framework requirements at retirement.
The VVB confirms compliance across all four at Validation. Ongoing compliance is confirmed at each Surveillance Audit.
The certified product must be certified to a recognized cement, clinker, or concrete product standard, and must be covered by a verified EPD meeting the requirements of Section 8.2.
Recognized product standards, by Functional Unit:
[/G-X7NH-0]A novelNovel binderBinder that does not conform to any recognized cement product standard is eligible only through the novel-binderNovel Binder pathway in Section 7.2.3, which sets the technical dossier requirements in lieu of standard conformity.
This Protocol is technology-agnostic. Any decarbonization pathway that meets the eligibility criteria in this section and the emissions intensity threshold in Section 7.3 may issue EACs. There is a published exclusion list to prevent low-integrity pathways from qualifying by default.
[/R-MQQH-0]Eligible pathways include, but are not limited to:
The following are excluded:
The VVB applies the primary-driver test in Section 7.2.2 to the renewable electricity and contractual fuel exclusion at Validation.
The exclusion list is not exhaustive. A pathway not named in either list is evaluated on the basis of the eligibility criteria in this section, and the emissions intensity threshold in Section 7.3.
AAn Supplementary Cementitious Material (SCM) partially substitutes Portland clinker in a blended cement or concrete, reacting within a clinker-based system rather than serving as a stand-alone binder. This includes traditional SCMs, being fly ash and ground granulated blast-furnace slag, and Novel SCMs, being SCMs other than fly ash and ground granulated blast-furnace slag, for example calcined clay, ground glass pozzolan, and natural pozzolans. Whether a material is an
An SCM or a Novel Binder is determined by its role in the certified product. A material that substitutes a share of clinker within a clinker-based system is an SCM. Where the same material replaces clinker as the primary binder, it iswhereas a Novel Binder and is treated under (Section 7.2.3.) Theremoves samethe materialneed mayfor be an SCM in one certified product and a Novel Binder in anotherclinker.
EACs must not be issued for any cement or concrete where a traditional SCM, being fly ash from coal-fired power plants or ground granulated blast-furnace slag, is the primary driver of the emissions reduction relative to the Baseline10., Thissubject exclusion applies regardless ofto the productexceptions standard under which the product is certified and the route by which it enters this Protocolbelow. A slag-dominant or fly-ash-dominant cement certified under EN 197-5, EN 197-6, or EN 15743 is treated the same as an equivalent cement certified under EN 197-1. The exclusion does not apply where the traditional SCM has been Beneficiated. It is not lifted by activation, or bythe anytraditional processingSCM thathas been Activated and is ordinarilyclassified partas ofa bringingNovel theBinder SCMunder toSection market7.2.3. Novel SCMs, and mixed-lever blends in which a traditional SCM is not the primary driver, remain eligible. The following definitions apply:
The following definitions apply:
The VVB applies the primary-driver test at Validation, using a qualitative assessment of the largest single contributor to the difference between the Project and Baseline EPDs. Where the VVB cannot establish from existing data whether a traditional SCM is the primary driver, or whether it has been Beneficiated or Activated, or whether the certified cement or concrete contains Portland clinker, it may require testing by an independent reviewer that is an accredited testing body. The independent reviewer is engaged directly by Isometric and must have no commercial or contractual relationship with Thethe Project Proponent.
An SCM is certified at the cement or concrete Functional Unit, either through the cement or concrete it is blended into or, where the SCM producer is Thethe Project Proponent, through a qualifying contract with the downstream producer, per Section 5.4. Replacement rates are delegated to the verified EPD under the relevant PCR. This Protocol sets no default replacement factors.
Each EAC must carry, as Certificate Attributes under Appendix D, the type and contribution percentage by mass of each SCM in the certified product or, where the binder in the certified product is a Novel Binder, its main constituents and the contribution percentage by mass of each. The contribution percentage is the constituent’s mass fraction of the certified product, as reported on the verified EPD or, on the Novel Binder pathway, the verified Life Cycle Assessment.
[/G-K4VF-0]A Novel Binder is a binder used in place of Portland clinker, such that the certified cement or concrete contains no Portland clinker, whether added directly or as Portland cement. Its primary reactive chemistry differs fundamentally from Portland clinker. Examples include geopolymers, alkali-activated binders, and electrochemically produced binders.
AProjects certifying a Novel Binder removesmust identify in the needPDD forwhether clinkerthe ratherNovel thanBinder substitutingconforms to a sharerecognized ofcement it,product which is what distinguishes it from a Novel SCM treated under Section 7.2.2. Its primary reactive chemistry differs fundamentally from Portland clinker. Examples include geopolymers, alkali-activated binders, and electrochemically produced binders. The distinction from a Novel SCM turns on this role, as set out in Section 7.2.2standard.
A Novel Binder certified under ASTM C1157, EN 15743, or an equivalent national or regional cement product standard enters through the main issuance path under Section 7.1. A standard is equivalent for this purpose where it is certified by a recognized national or regional standards body and sets composition and performance requirements at least as stringent as the named EN or ASTM standards, which the VVB confirms at Validation. WhereA thecement certified product'sunder composition permits a traditional fossil SCM to be the primary driverone of thethese reductionstandards that contains Portland clinker, for example a slag-dominant cement under EN 15743, theis VVBnot appliesclassified theas primary-drivera testNovel inBinder and is assessed under Section 7.2.2 before issuance, andincluding the exclusionprimary-driver in Section 7.2.2 appliestest.
A novelNovel binderBinder that fits no recognized cement product standard, or holds only a product-specific technical approval, routes through the novelNovel binderBinder pathway, where any approval is submitted as supporting evidence rather than as a substitute for review. The Project Proponent must submit a technical dossier to Isometric covering:
The VVB reviews the technical dossier at Validation. Where equivalence to the reference conventional cement type cannot be established from the dossier alone, for example, because the required mechanical performance or durability tests were not conducted to a recognized test standard, or because no standard exists for the property under review, Isometric will engage an independent reviewer with binder-chemistry, mechanical-performance, or durability expertise, as applicable, to confirm the equivalence-determining tests. The independent reviewer is engaged directly by Isometric and must have no commercial or contractual relationship with Thethe Project Proponent.
Isometric defers to the clinker-equivalent translation table in Appendix C to identify the closest functionally equivalent conventional cement type and its mass-equivalence factor, typically 1 : 111. The novelNovel binderBinder then enters the main issuance machinery via that reference equivalence, with Baseline and matching rules applied as for the reference cement type. Isometric maintains the equivalence table and re-evaluates each entry at intervals of no more than 12 months, and sooner where new data, an updated dossier, or a change in standard conformity materially affects the applicable reference cement type or mass-equivalence factor.
For a Novel Binder on the novel-binderNovel Binder pathway, the verified Life Cycle Assessment serves in place of the verified EPD for the Carbon Intensity of the certified product. This Protocol sets no default replacement factors.
Each EAC must carry the SCM or novel binder type (non-beneficiated fly ash, beneficiated ponded ash, electric arc furnace slag, calcined clay, or novel binder) and the contribution percentage by mass of each, being the constituent's mass fraction of the certified product as reported on the verified EPD, as one of the Certificate Attributes in Appendix D.
The certified product must have a Carbon Intensity at or below the emissions intensity threshold applicable to its Functional Unit, production region, and production vintage. For output produced from 2025 to 2029, the threshold is Band C of the GCCA Low-Carbon Ratings for cement and concrete. For output produced from 2030 onwards, the threshold tightens to Band B12.
[/R-FPAG-0]Bands are regionalized. Countryand country-level Band C and Band B values for cement, as of January 2026, are set out in Appendix B. The Project Proponent must apply the country value published for the country in which the certified product is produced, per Appendix B. Where the country is not listed, the global values apply.
The corresponding threshold for a clinker EAC is the Band C or Band B value at a 1.0 clinker-to-cement ratio (100 percent clinker) for the applicable country. The corresponding threshold for a concrete EAC is derived from the applicable cement band using the cement-to-concrete ratio recorded on the verified EPD.
The applicable band is set by production vintage. A quantity of certified output is assessed against the band in effect for the year of the Reporting Period in which it was produced. Once EACs have been issued against a production vintage, the band that applied at that vintage governs those EACs, and a subsequent tightening of the threshold does not retroactively disqualify them. On renewal of the Crediting Period, the Project is re-validatedValidated against the band applicable to the new Crediting Period, per the re-validation requirement of the Isometric Standard.
The threshold applies at Validation, at each subsequent Surveillance Audit, and at re-validationValidation. A Project whose emissions intensity rises above the band applicable to a production vintage may not issue EACs for the Reporting Period of that vintage.
Catalytic Impact asks whether a Project drives genuine market transformation of the cement sector, beyond producing a lower-carbon product. It is distinct from the Additionality assessment in Section 5.5: a Project may satisfy the Additionality pillars without meaningfully advancing the sector's decarbonization frontier.
Every Project Proponent must submit a Catalytic Impact narrative at Validation13. The narrative is disclosed on the Registry and Beneficiaries assess catalytic impact against their own framework requirements at retirement.
[/R-3B65-0]Buyer thresholds vary and illustrative benchmarks include: a credible path to at least 10,000 tonnes CO₂e per year of emissions reduction by 2030 and 100,000 tonnes per year by 2035 (Meta Sustainable Materials Program), a decarbonization potential of at least 50 percent LCArelative abatementto an intervention baseline for cement and concrete (AIM Platform Standard V1.0, Table 8), and system-level impact demonstration for consequential claims (SBTi V2.0 C27.5).
The narrative must address the following five items:
Where the intervention uses a biomass feedstock, Thethe Project Proponent must apply Section 2.5 of the Biomass Feedstock Accounting Module v1.4, to screen out feedstocks whose diversion to the intervention would displace prior uses to a higher-emitting substitute or lead to indirect land use change. The Project is eligible for EAC issuance only if Thethe Project Proponent satisfies one of the market displacement tests ML2, ML3, ML4, ML5, ML6, or ML7. The criterion is confirmed by the VVB at Validation and reconfirmed at each Surveillance Audit.
This section sets out the calculation methodology for all EACs issued under this Protocol: how the Carbon Intensity of a certified product is measured, how allocation is handled, EPD requirements and how Baselines and Emission Reduction Value are constructed.
The cross-cutting principles for the GHG accounting boundary, Uncertainty, default emission factors, and proxies are set in Section 2.5.2.2, Section 2.5.4, and Section 2.5.6 of the Isometric Standard.
The Carbon Intensity of a certified product is the value reported on the verified EPD prepared under the applicable PCR per Section 8.2, expressed in kg CO₂e per Functional Unit. That value is carried on the EAC as one of the Certificate Attributes under Appendix D.
A PCR sets the rules under which an EPD is calculated for a defined product group, including the GHG accounting boundary, allocation rules, data quality requirements, and reporting conventions. The PCR is what makes EPDs for the same product type comparable across producers, and what makes the reported Carbon Intensity a defensible basis for an EAC.
An EPD for the purpose of underlying product certification is acceptable under this Protocol where it meets all of the following:
[/G-TEJS-0]The Carbon Intensity carried on the EAC, and the Baseline value under Section 8.4.1, are the total for life cycle stages A1 to A3 only, including where an EPD also reports other life cycle stages or Module D.
The Project Proponent must apply the PCR of the production jurisdiction where one covers the certified product. Where no PCR exists in the production jurisdiction, or where the jurisdiction's PCR does not cover the certified product, Thethe Project Proponent must apply one of the following as fallback:
Where an accepted EPD is certified under the International EPD System as an EPD of a product recently on the market, as defined in Section A.9.5 of the International EPD System's General ProgrameProgramme Instructions, it must meet the requirements of Section A.9.5 of the International EPD System's General ProgrameProgramme Instructions (GPI 5.0.1)15 in full. This includes the required cover-page and product-information disclaimer; the condition that any LCI data drawn from a period shorter than one year of production be proven to be conservative relative to one-year data, accounting for seasonal variations and productivity effects (A.9.5); and the obligation to update and re-verify the EPD within six months of one year of production data becoming available, failing which the EPD will be depublished. Equivalent provisions in other recognized EPD programesprograms apply on the same basis.
The EPD must be verified by a VVB (the “EPD VVB”) accredited under ISO 14065 and ISO/IEC 17029 for the applicable PCR, being accreditations recognized under Section 4.1 of the Isometric Standard, or by a body holding an equivalent accreditation recognized by the EPD program operator for that PCR, per Section 3.13 of the Isometric Standard.
[/G-5R66-0]Some EPD programs allow an EPD produced with a pre-verified tool to be signed off by an internal reviewer rather than an EPD VVB. Such an EPD is acceptable only where:
The Project Proponent engages the EPD VVB. Isometric selects and engages the VVB that conducts Project Validation and Surveillance Audits for EACs registered on the Isometric Registry, perconsistent with the Conflicts of Interest requirements of the Isometric Standard. A single body holding both accreditations may perform both functions, but each function is engaged by a different party.
TheAnnex A of Smart EPD Part B v4.0PCR for Cementitious Materials 1000-017 (the CCS add-on) is the default method for the CCUS-specific components of the EPD regardless of the production jurisdiction, per Section 916.
Every EPD for a CCUS product is verified as set out under EPD verification above. How its conformity with the add-on is checked depends on the route Thethe Project Proponent follows:
The adjustment statement forms part of the PDD. For each adjustment, it must set out:
[/G-1RA3-0]The Project Proponent must update the adjustment statement where a new or re-verified EPD is relied on, or where the add-on or a binding rule it relies on changes. The VVB reviews the updated statement before any EACs are certified against it.
An adjustment must not result in a lower reported Carbon Intensity than applying the add-on in full.
[/G-ND5R-0]The following principles apply to any EPD used for EAC issuance under this Protocol:
An EPD may be relied on for EAC issuance provided that Thethe Project Proponent shows at each Surveillance Audit that the Carbon Intensity stated on the EPD remains an accurate representation of the EACs being issued.
To do this, Thethe Project Proponent must submit a sensitivity analysis at each Surveillance Audit, which the VVB verifies. The analysis covers the time up to that Surveillance Audit, starting from the later of:
The analysis must:
The EPD remains acceptable where the observed Carbon Intensity does not exceed the reported Carbon Intensity by more than the materiality threshold. The threshold is that of the applicable PCR or, where the PCR is silent, of the underlying ISO 21930 or EN 15804 provisions.
An observed Carbon Intensity lower than the reported value does not change the value carried on the EAC. To issue against an improved Carbon Intensity, Thethe Project Proponent must obtain a new verified EPD.
Where the threshold is exceeded, EACs issued after the analysis is verified must carry [math: CI_{Observed}] in place of the Carbon Intensity reported on the EPD, until either:
[/G-921D-0]The Emission Reduction Value is recalculated accordingly, and the product must continue to meet the emissions intensity threshold in Section 7.3.
The understatement across all EACs issued during the period covered by the analysis must be compensated through Cancellation, until the total Emission Reduction Value of the Canceled EACs equals or exceeds [math: U], as defined in Equation 1. Cancellation applies first to EACs held by Thethe Project Proponent, and then to future issuances, per Section 5.6.1 of the Isometric Standard.
[math: U = (CI_{Observed} - CI_{Reported}) \times N_{Issued}]
Equation 1
Where:
For a Project using the current EPD as a Baseline (BL1), the sensitivity analysis must also cover the BL1 Baseline value. A deviation in that baselineBaseline value is handled under Section 8.4.2 and does not trigger Cancellation.
At each Issuance Review, Thethe Project Proponent must confirm in a short statement that there has been no material change to the certified product since the EPD, or the most recent sensitivity analysis, was verified. Where there has been a material change, Thethe Project Proponent must submit an interim sensitivity analysis before issuance.
An EAC issued under this Protocol represents a quantified reduction against a Baseline. The Baseline is the Carbon Intensity of the counterfactual product that the certified product most likely displaced, expressed in kg CO₂e per Functional Unit. This section sets how the Baseline is constructed and matched to the certified product (Section 8.4.1), how it is updated over time (Section 8.4.2), how the Emission Reduction Value carried on each EAC is calculated (Section 8.4.3), and how the Baseline is applied through Validation, Issuance Review, and Surveillance Audit (Section 8.4.4).
Every EAC issued under this Protocol carries a Carbon Intensity, expressed in kg CO₂e per Functional Unit, together with a Baseline value, Baseline type, Baseline source, Baseline vintage and Emission Reduction Value, as Certificate Attributes under Appendix D. This applies regardless of the claim type the Beneficiary uses at retirement.
The Baseline is selected using Table 218. The Project Proponent must apply the first row whose eligibility criteria are met. Section 8.4.4 sets how the Baseline is validated and reviewed.
For the purposes of Section 8.4, an intervention is a discrete change to the configuration of the certified facility with an identifiable commissioning date: the installation of new equipment, the commissioning of a fuel or feedstock switch, or a process change documented in the Project's engineering records. General operational drift, ongoing efficiency work and incremental adjustment of an existing configuration are not interventions. The Project Proponent must list each intervention included in the Project, with its commissioning date, in the Project Design Document.
[/G-40MC-0]References in Table 2 to the GMA+RMI framework are to Book and Claim for Cement and Concrete (Center for Green Market Activation and RMI, Version 1, January 2026).
Table 2. Baseline definition
Criteria | Baseline type | Eligibility Criteria | Baseline value | Evidence |
|---|---|---|---|---|
BL1 | Current EPD, interventions separated | The certified product is produced at an existing facility or a new facility, and the impact of all the interventions included in the Project can be separated from the product Carbon Intensity on a recurring basis (for example, CCUS). | Carbon Intensity of the certified product excluding the contribution of the interventions included in the Project, calculated under the same PCR as the certified product's EPD. | Verified EPD for the certified product reporting the contribution of the interventions included in the Project. |
BL2 | Pre-intervention EPD | The certified product is produced at an existing facility, including where the intervention is an upstream retrofit, and the intervention does not shift the product to a different product type. | Carbon | Verified pre-intervention EPD. |
BL3 | Regional benchmark | The Project Proponent has demonstrated ineligibility for the rows above, and an approved benchmark listed in Appendix E of the GMA+RMI framework covers the production region and product, with a data year within 5 years of EAC issuance | Value from the approved regional benchmark source, matched to the certified product under Section 7.2 of the GMA+RMI framework. | Statement from |
BL4 | GCCA Band D fallback | The Project Proponent has demonstrated ineligibility for the rows above | Top of the GCCA Low-Carbon Ratings Band D for the country of production, matched to the certified product, under Section 7.2 of the GMA+RMI framework. Where no country-level rating is available, the top of the global Band D. | Statement from |
The Baseline is updated over time19. Update cadence depends on Baseline type. Table 3 sets out the update rules.
[/G-SD1V-0]Table 3. Dynamic Baselines
Criteria | Baseline type | Update cadence | Transition on expiry or invalidation |
|---|---|---|---|
BL1 | Current EPD, interventions separated | Set at Validation from the verified EPD for the certified product. Reconfirmed at each Surveillance Audit, per Section 8.3.1. Recalculated when a new verified EPD is obtained. | Where the Surveillance Audit check for continued relevance of the EPD |
BL2 | Pre-intervention EPD | Fixed to the pre-intervention EPD until that EPD expires, and for no more than 5 years from its issue date. | On expiry of the pre-intervention EPD, transitions to the lesser of the pre-intervention EPD value and the market average for the certified product (BL3, or BL4 where no benchmark applies). |
BL3 | Regional benchmark | Updated with each new publication of the approved regional benchmark. The data year must be within 5 years of EAC issuance. | Where no publication with a data year within 5 years of EAC issuance is available, BL4 applies. |
BL4 | GCCA Band D fallback | Tracks new publications of the GCCA Low-Carbon Ratings for the country of production | Updated in line with new GCCA Low-Carbon Ratings publications. Where an approved benchmark becomes available for the production region and product, the Baseline moves to BL3. |
A Baseline update takes effect at the next Issuance Review. When a new benchmark or new GCCA publication is released mid-Reporting Period, the update applies from the next Issuance Review onward.
For BL4, the lower and upper bounds of Band D, and the Emission Reduction Value calculated against each, are additionally carried as Certificate Attributes under Appendix D, for Buyer transparency.
An EAC is issued against the Baseline in effect at the Issuance Review at which the EAC is issued. When the Baseline is updated, previously issued EACs are not recalculated. Each EAC carries the Baseline value, Baseline type, Baseline source and Baseline vintage in effect at its issuance as Certificate Attributes under Appendix D.
Each EAC carries an Emission Reduction Value calculated as the difference between the Baseline Carbon Intensity and the Carbon Intensity carried on the EAC. The Emission Reduction Value is the equivalent of the intervention outcome under the AIM Platform Standard20.
[math: ERV = CI_{Baseline} - CI_{EAC}]
Equation 2
Where:
The Project Proponent may elect to report the contribution of each decarbonization lever to the Emission Reduction Value as a Certificate Attribute under Appendix D. Where it does so:
This disclosure is for information only. It does not change the Emission Reduction Value, and no part of the Emission Reduction Value may be claimed separately.
For Validation, Thethe Project Proponent must include the following in the Project Design Document:
At each Issuance Review, Thethe Project Proponent must state the Baseline value, type, source and vintage applied, including any update under Table 3. Isometric confirms that this is the Baseline in effect under Table 3.
At each Surveillance Audit, the VVB must confirm that the correct Baseline has been applied under Tables 2 and 3 and, where Thethe Project Proponent reports the contribution of each decarbonization lever, that those contributions follow the source or method validated.
This section sets out the rules that apply to a Project relying on CCUS as a decarbonization pathway.
The following storage pathways for captured fossil and process CO₂ are default-eligible under this Protocol:
The following utilization pathways are eligible only where Thethe Project Proponent demonstrates that the utilization meets the Long-Term Storage definition and MRV verification confirms that the bound CO₂ fraction stays bound over the relevant time horizon:
The following utilization pathways are excluded:
Storage of captured CO₂ must be verified by an accredited MRV protocol, as required by Smart EPD Part B PCR for Cementitious Materials 1000-017, Annex A, Storage Verification. The verified EPD for the certified product must reference the monitoring report produced under that MRV protocol for the CO₂ captured during the Reporting Period2120. The monitoring report must identify the storage operator and site, state the injected quantity, describe the monitoring program, including how it detects reversals for closed-system storage, and confirm Long-Term Storage as defined in Section 9.2. Where the storage jurisdiction operates its own MRV protocol, that protocol applies; where none exists, the MRV protocol referenced must meet ISO/IWA 42:2022 (per Smart EPD Part B v4.0 Section Storage Verification)21.
A separate Certificate of Storage document is not required where the MRV protocol output covers the fields set out above. Where a producer has already produced a Certificate of Storage in the format used by the GCCA Chain of Custody Rulebook2221, that document may be submitted in lieu of a separate MRV output if it references an accredited MRV protocol and covers the same fields.
The VVB confirms the MRV reference at Validation. The verification routes for the EPD of a CCUS product, including the accreditation required, are set in Section 8.2.
Captured CO₂ must be stored in a form that qualifies as Long-Term Storage. Long-Term Storage is the definition applied by the local CO₂ storage regulatory body's MRV protocol, or, where no such regulatory body or MRV protocol exists, GWP100 per ISO/IWA 42:2022 (per Smart EPD Part B v4.01000-017, Section:Annex A, Long-Term Storage). Storage that does not qualify as Long-Term Storage is ineligible for EAC issuance.
The Project Durability Threshold under this Protocol is 1,000 years, matching the default in Section 2.5.7 of the Isometric Standard. Every storage form eligible under this Protocol is expected to exceed 1,000 years, whether through geological permanence or through storage in the built environment, so a form that qualifies as Long-Term Storage but cannot demonstrate 1,000-year durability is not eligible under this Protocol. The Project Durability Threshold is recorded on the EAC as a Certificate Attribute.
[/G-JM30-0]The reversal-accounting route depends on whether the captured CO₂ is held in a closed-system or an open-system:
The Project Proponent must also complete the Risk of Reversal assessment detailed in Appendix A, which categorizes the Project's Risk of Reversal. The Risk of Reversal category informs the monitoring program and the reversal risk treatment.
[/G-68YN-0]For closed-system storage, a Reversal is observable and is compensated after the event under Section 9.5. For open-system storage, the Risk of Reversal is "No observable risk" and reversal risk is instead accounted for as an uncertainty discount held inside the Carbon Intensity carried on the EAC, per Section 8.3 of Isometric's CO₂ Storage via Carbonation in the Built Environment Module. The mechanism is further set out in Section 9.2.1.
The verified EPD includes the stored CO₂ as a deduction within the reported Carbon Intensity. Under Smart EPD Part B v4.01000-017, this amount is the verified Sequestered CO₂, being the quantity captured, measured, and verified by an independent third party as put into geological storage or chemically bound through production of synthetic carbonated materials (Smart EPD Part B v4.01000-017, Annex A). Should regional PCRs adopt CCUS provisions, the same principle applies to whatever parameter that PCR uses to represent stored CO₂ within the reported Carbon Intensity.
The Sequestered CO₂ is the deduction that drives the reported Carbon Intensity below the level it would carry without CCUS. A Reversal releases that stored CO₂ back to the atmosphere. In an open-system a Reversal is not observable, so there is no event to compensate against after issuance, unlike closed-system storage under Section 9.5. The reversal risk is instead accounted for at Issuance as an uncertainty discount that reduces the certified deduction, so the Carbon Intensity carried on the EAC is higher than the value reported on the EPD.
The uncertainty discount, its derivation, and the Project-specific reassessment procedure are set by Section 8 and Appendix A of Isometric's CO₂ Storage via Carbonation in the Built Environment Module. The Module models the fate of CO₂ stored in the built environment across the end-state usesuse cases, including but not limited to: construction, demolition, downcycledowncycling and reuse cycle over the 1,000-year durability horizon. These use cases account for the reversal mechanisms that apply to built materials, themselves including but not limited to: exposure to low-pH fluids, fire, and high-temperature recycling. Under the Module's conservative scenario the modeled average loss at 1,000 years is 6% of the stored CO₂, which is the default discount (see details of the modeling and calculation for the default discount value in Section 8.2 of the Module). The discount is applied to the Carbon Intensity as:
[math: CI_{EAC} = CI_{EPD} + (d \times M_{Stored})]
Equation 3
Where:
The Emission Reduction Value per Section 8.4.3 is calculated using [math: CI_{EAC}], so the discount flows through to a reduced Emission Reduction Value without further adjustment.
A Project Proponent may seek a discount other than the default by submitting an Uncertainty Discount Assessment, which produces a Project-specific model determination of reversal risk from submitted data, per Section 11.4 of the CO₂ Storage via Carbonation in the Built Environment Module. The evidence that may support a reassessment, and its effect on the discount, is limited to the documentation categories in Appendix A, Table A1.2 of the Module. The Assessment must identify the open-system pathway, being CO₂-cured concrete, captured CO₂ mineralized into aggregate, or captured CO₂ mineralized into an SCM, and must characterize the applicable reversal mechanisms, such as exposure to the low-pH-fluid fluids, fire, and high-temperature- recycling, because the fate profile differs across the pathways. A reassessment may lower or raise the discount. Where the submitted evidence demonstrates lower exposure than the Module's conservative scenario, the discount is reduced accordingly. Where the Project-specific model determination returns a higher expected loss, the discount is raised.
The VVB confirms [math: M_{Stored}] and the applied discount at Validation. The discount is reconfirmed at each Surveillance Audit and reassessed at the renewal of the Crediting Period, or sooner where new scientific research materially changes the reversal-risk basis.
Emissions and fugitive leakage from CO₂ transport between the cement facility and the storage site must be included in the EPD's cradle-to-gate life cycle inventory for sequestration, [math: LCI_{seq}], per Smart EPD Part B v4.01000-017 Annex A. Any detected CO₂ Leakageleakage during intermediate storage, transportation, or use must be reported and accounted for in the CCUS emission balance and made available at Issuance Review. This Protocol sets no separate transport-leakage cap; the requirement is that transport emissions and fugitive leakage are included in the Carbon Intensity value on the EPD, so they raise it by reducing the net stored CO₂ certified, and that value is what the EAC carries.
Biogenic CO₂ emitted from the production process is treated as climate-neutral within the EPD for the product, per EN 15804+A2 and the GWP-biogenic separation applied by Smart EPD Part B v4.01000-017. The treatment of biogenic CO₂ that is captured and durably stored (stored biogenic CO₂) follows the applicable PCR, per Section 8.2. Under Smart EPD Part B v4.01000-017, stored biogenic CO₂ is deducted within the reported Carbon Intensity. Under EN 15804+A2, it is currently excluded from the reported Carbon Intensity.
The fossil and biogenic shares of the captured stream are determined by mass balance based on declared and verified carbon-bearing inputs, being fuel inputs and any carbonate feedstock inputs, per the applicable PCR. This applies to any CO₂ stream arising from the certified production process, however generated, including flue-gas capture and process-inherent separation such as indirect or electrochemical calcination. Where the mass balance is in question, for example under complex multi-fuel co-firing or a material inconsistency between declared inputs and observed operations, the VVB may require supplementary evidence, including isotopic (¹⁴C) verification of the captured stream per ISO 13833 or an equivalent standard.
[/R-S8C3-0]An EAC may carry two Carbon Intensity values:
[/G-DJNZ-0]Where biogenic CO₂ is durably stored, the storage may route to Isometric's Bio-CCS Protocol as a separate Carbon Dioxide Removal Certificate. The rules governing parallel participation in this Protocol and the Bio-CCS Protocol, including the treatment of shared emissions and the prohibition on double-countingremovals, are set in Section 9.6.
EACs issued under this Protocol make no Buffer Pool contribution. This follows the treatment of Environmental Attributes in Section 2.5.8 of the Isometric Standard: reversal risk for an EAC is managed through the reversal compensation routes in this section and, for open-system storage, through the uncertainty discount in Section 9.2.1.
A verified Reversal releases stored CO₂ that the verified EPD had credited as a deduction within the reported Carbon Intensity. Because that deduction is what lowered the Carbon Intensity, a Reversal means the Carbon Intensity carried on the affected EACs was lower, and their Emission Reduction Value higher, than the actual outcome, by the quantity of stored CO₂ released.
For closed-system storage, a verified Reversal is compensated through one of the following, depending on the Project:
[/G-17HM-0]The quantity of stored CO₂ released in a Reversal is converted into the number of EACs to be Canceled using the one-to-one relationship between stored CO₂ and Emission Reduction Value:
[math: N_{Canceled} = \frac{Q_{Reversed}}{ERV_{Unit}}]
Equation 4
Where:
Rounding up is the conservative choice where the released quantity does not divide into whole Functional Units. Because no pool is pre-funded, a Project not operating under a recognized equivalent regulatory scheme must secure continuity of the reversal obligation through the storage-operator-continuity dossier required at Validation under Section 9.7.
A Project relying on CCUS where the captured stream is a mixture of biogenic and fossil CO₂ may participate in this Protocol and in the Isometric Bio-CCS Protocol in parallel. The routing of the captured stream between the two programs follows the origin of the CO₂, verified by mass balance:
The Project Proponent must apply the routing on the basis of verified physical origin. Where the mass balance cannot cleanly apportion the captured stream, Thethe Project Proponent applies the conservative fallback and routes the ambiguous share to neither program until the split can be verified. The mass-balance evidence rules that determine the fossil and biogenic shares are set in Section 9.4.
Each tonne of stored biogenic CO₂ may be certified once only. For each Reporting Period, Thethe Project Proponent must elect one of the following routes for each tonne and declare the quantity routed each way at Issuance Review:
At each Issuance Review, Isometric confirms that no tonne counted on the EAC has been certified as a removal.
Emissions accounting may overlap across the two programs. Allocation rules for shared emissions between the two programs will be set in a future joint update to this Protocol and the Bio-CCS Protocol.
Article 6 international transfers under the Paris Agreement operate at the government level and are treated separately from Project-level EAC or Bio-CCS certificate issuance. This Protocol takes no position on Article 6 accounting for the same underlying activity.
The storage operator responsible for injecting and monitoring the captured CO₂ is typically a separate legal entity from the cement producer. Continuity of monitoring and stewardship obligations across the operator's tenure is a condition of eligibility for a CCUS-backed EAC.
The MRV protocol reference required under Section 9.1 must identify the regulatory framework under which the storage site is permitted, and must identify the storage operator holding the permit for the Reporting Period. Where the storage jurisdiction operates a long-term stewardship regime that transfers monitoring obligations from the operator to the state or to a designated successor after a defined post-closure period, the MRV protocol reference must name that regime.
[/R-0J3D-0]Where the storage operator changes during a Reporting Period or a Crediting Period, Thethe Project Proponent must record the change in the PDD and must submit updated permit and operator identification with the next Issuance Review. Isometric will confirm at Issuance Review that monitoring and stewardship obligations have transferred without gap. A handover recorded without a gap does not trigger a Reversal under Section 9.5.
Where the Project does not operate under a recognized equivalent regulatory scheme under Section 9.5, Thethe Project Proponent must submit a storage-operator-continuity dossier at Validation. The dossier must identify:
A Project operating under a recognized equivalent regulatory scheme relies on that scheme for continuity, including its financial-security requirement, and is not required to submit the dossier.
The Crediting Period is unchanged and is set under Section 11.5. After the Crediting Period ends, monitoring for Reversals continues for the duration required by the storage jurisdiction's long-term stewardship regime. Where the jurisdiction has no statutory stewardship regime, monitoring continues for 15 years after the end of the Crediting Period. Active monitoring during the Crediting Period is unchanged and follows the site MRV protocol and the Surveillance Audit cadence.
[/G-W64K-0]Stewardship of the storage site after the Project's Crediting Period ends is governed by the storage jurisdiction's regime. Safeguarding obligations that follow the operator handover are set out in Section 6.
The separation of an Environmental Attribute from its physical product introduces double counting risk. The cross-cutting framework that governs this exposure is set in Section 5.7 of the Isometric Standard, which aligns with the categories of double counting in ISO 22095-3:2026. This section sets the cement-specific safeguards that operate in relation to that framework.
Once an EAC has been issued for the Environmental Attribute of a quantity of cement, concrete, or clinker, that Environmental Attribute has been separated from the physical product. The Physical Recipient of the de-attributed product must not make any quantitative claim about the Carbon Intensity or emissions reduction of that product, whether in a greenhouse gas inventory, a product or whole-building Life Cycle Assessment, a green-building rating scheme (for example LEED or BREEAM), or marketing. The statements the Physical Recipient may make are set in Section 10.2.
The Project Proponent must meet the requirements in Section 10.1.1 (Physical Recipient Information), Section 10.1.2 (Issuance Reconciliation) and Section 10.1.3 (Exclusivity).
The Project Proponent must provide the Physical Recipient the Baseline value and Baseline vintage recorded on the EAC under Section 8.4.2, being the conventional-cement benchmark used as the input to the Emission Reduction Value calculation in Section 8.4.3. The value and vintage provided to the Physical Recipient must be identical to those recorded on the EAC, not the benchmark current at the time of delivery, so that the Baseline the Physical Recipient reports and the Emission Reduction Value the Beneficiary reports trace to the same Baseline. This is the value the Physical Recipient reports, as set in Section 10.2.
[/R-M6Z2-0]The Project Proponent must disclose that the Environmental Attribute of the product has been severed for issuance as an EAC, and must state the Baseline value and Baseline vintage to be used2322. The disclosure must be made through the following channels:
Where the program operator supports neither a notes field nor a status flag, the cover page alone meets this requirement. The Project Proponent must state in the Project Design Document which of these channels its program operator supports, and the VVB confirms this at Validation.
The Project Proponent must reconcile EAC issuance against verified production at each Issuance Review, such that the EACs issued for a Reporting Period, plus any Environmental Attribute retained on physical product, do not exceed the verified production volume for that Reporting Period. This reconciliation is a quantitative control against over-issuance. As part of this reconciliation, Isometric, as Registry operator, confirms that the Baseline value and Baseline vintage on the EPD cover page match those recorded on the EAC.
[/G-FV08-0]The Project Proponent must ensure that each unit of reduction certified under this Protocol is allocated to at most one EAC, coupled to at most one EPD or other product Carbon Intensity claim, and not booked to more than one registry. The Project Proponent must declare at Validation every program through which the Environmental Attribute of its output is sold or certified, and must confirm at each Issuance that no quantity of certified production has been certified more than once.
[/R-VGPC-0]The same Environmental Attribute must not be issued, transferred, or retired on any other registry or crediting program2423. Inter-registry transfers are out of scope, aligned with Section 5.7.2 (Inter-Registry Operability) of the Isometric Standard. Isometric will coordinate with other registries to prevent cross-registry double counting and is open to pilot studies.
The Project Proponent must meet these requirements through one of the two routes below, elected at Validation and identified in the PDD. A change of route must be approved by Isometric and confirmed by the VVB at the next Surveillance Audit.
[/G-Q4QJ-0]The Project Proponent must also engage a third-party verifier to issue and publish periodic verification statements confirming that no unit of reduction has been double-allocated, double-coupled, or double-booked over the covered period. The statements must cover all certified production, with no gaps between the periods they cover. Their cadence and content are set by the third-party verifier and are not prescribed by this Protocol, but must be stated in the inventory management methodology and confirmed at Validation. The VVB reviews the verification statements at each Surveillance Audit and confirms consistency with the validated inventory management methodology.
[/G-YEEW-0]Material changes to the inventory management methodology during the Crediting Period must be notified to Isometric and re-verified by the VVB at the next Surveillance Audit.
[/G-J3AH-0]The Physical Recipient is the party that takes delivery of the physical product after its Environmental Attribute has been severed and issued as an EAC. The Environmental Attribute does not travel with the physical product. It travels with the EAC, and the Beneficiary of that EAC is the party entitled to report it. The physical product carries the Baseline value and Baseline vintage recorded on the EAC, and that is the value the Physical Recipient reports.
The Physical Recipient may make factual statements about its use of the certified product and its experience with the producer, including publicizing that it sourced the product from a named producer and that the producer is engaged in decarbonization, subject to any contractual disclosure and confidentiality terms. It must not describe the product as sustainable or low-carbon, and must not state or imply a Carbon Intensity lower than the Baseline value, an emissions reduction, a percentage improvement, or a GCCA Low-Carbon Rating band for the product. Where the Physical Recipient uses the product in a greenhouse gas inventory, a product or whole-building life-cycleLife assessmentCycle Assessment, or a green-building rating scheme, it must use the Baseline value recorded on the EAC.
No residual mix calculation is required for EACs under this Protocol. This applies to both a market-wide residual mix and a per-product residual emission factor.
Proportional allocation spreads the Environmental Attribute evenly across output, so there is no remainder within the Book and Claim Boundary (Section 5.1) from which Environmental Attributes have been concentrated, and therefore no residual to account for.
A value-chain layer is a stage in the clinker, cement and concrete value chain at which the certified product enters an organization's own reporting. Section 5.4.1.1 of the Isometric Standard permits more than one organization to be named as a Beneficiary of a single Retirement, provided each claim is distinct and non-overlapping, and requires this Protocol to set the number of Beneficiaries permitted and the basis on which their claims are distinguished. Under this Protocol, co-claiming lets more than one organization along the cement value chain reflect the same EAC in its own reporting, with one claimant per value-chain layer and a maximum of four claimants. The cement value-chain layers are2524:
The primary Beneficiary can add co-claimants from other value-chain layers as additional Beneficiaries following their initial retirement.
Co-claiming is permitted only between organizations occupying distinct and non-overlapping roles in the value chain. Where a single organization occupies more than one value-chain layer for a given EAC, for example a contractor that produces the concrete it installs, or an owner-occupier, it attaches at one layer only. Where the same reporting entity occupies more than one layer, those roles overlap, and a second attachment would count the same reduction twice within one greenhouse gas inventory.
Where two or more organizations could attach at the same layer, for example a main contractor and the subcontractor that purchased the concrete, only one may attach. The Beneficiary that retires the EAC determines which organization is added at that layer.
The Isometric Registry does not enable Rebundling, meaning the re-attachment of an EAC's Environmental Attribute to the carbon claim of a physical product. The Environmental Attribute is severed from the physical product at Issuance, per Section 10.1, and stays with the EAC until Retirement.
The Project Proponent, or any other holder of an EAC, may sell an EAC in the same commercial transaction as a physical product, including a physical product other than the one from which the Environmental Attribute was severed. This is a paired sale. In a paired sale:
[/R-F5J1-0]The stages of an EAC's life on the Isometric Registry are set in the Certificates section of the Isometric Standard: Issuance, Delivery and Transfer, and end of life through Retirement, Expiry, or Cancellation. This section sets the cement-specific requirements at each stage.
An EAC is issued only after the physical low-carbon product has entered use. For clinker and cement the trigger is sale or shipment, whereas for concrete it is deployment2625. This prevents issuance against a product that is never sold or used.
The Project Proponent must provide evidence of sale or deployment at Issuance. Acceptable evidence is a bill of lading, delivery ticket, invoice, or declaration of performance.
The interval between production and issuance must be as short as practicable. Section 3.4 of the Isometric Standard requires this Protocol to set the maximum period between production of the underlying product and the EAC issuance request. ThisEach Protocolissuance setsrequest nomust fixedbe maximumsubmitted intervalwithin 18 months of the earliest production date it covers.
An EAC issued under this Protocol carries the Certificate metadata for EACs defined in Section 5.1 (Certificate Attributes) of the Isometric Standard, plus the Protocol-specific attributes set out in Appendix D. All attributes are recorded on the Isometric Registry and are publicly visible, subject to the data restriction rules in Section 5.7.
This Protocol provides no conversion route between the clinker, cement, and concrete Functional Units, and Retirement for Conversion under Section 5.4.2 of the Isometric Standard is not available. An EAC remains at the Functional Unit against which it was issued, per Section 4, and must not be retired to enable issuance of an EAC at another Functional Unit.
This Protocol specifies no numeric conversion factors for issuance. The quantity and carbon-intensity relationships between clinker, cement, and concrete are captured within the EPD under the relevant PCR. Comparability between product types is governed by the framework under which the Beneficiary reports. Appendix C provides example conversion factors, based on the GCCA equivalence methodology, that a Beneficiary may use to report an EAC across Functional Units, where the relevant reporting framework allows.
The primary flow of an EAC is downstream, from Thethe Project Proponent toward the end user. Cross-claim direction and value-chain layer mechanics are set in Section 10.4.
An EAC issued under this Protocol must not be retired at the producer level to alter the producer's own product Carbon Intensity or EPD.
Requirements that prevent the same reduction being issued, coupled to an EPD or booked on a registry more than once are set in Section 10.1.
An EAC must be retired within 24 months of the endproduction date of itsthe productionproduct vintageit yearrepresents. If it is not, otherwise it expires. After expiry itand can no longer be transferred or retired.
This matchesextends the 12-month default expiry period in Section 5.4.3 of the Isometric Standard.
The 24-monthlonger window appliesis justified by the cement and construction procurement cycle, consistent with the exception in SBTi V2.0 Section C25.5 exceptionfor tolonger timeframes justified by the 12-monthtypical default.production Thecycle justification isof the cementrelevant andgood. construction procurement cycle: cementCement is an input to multi-year construction programs,; lead times between production, project award, construction, and buyer reporting can exceed 12 months, and there is no liquid spot market that would let Buyers time-match purchases precisely.
Section 3.4 of the Isometric Standard sets a default Crediting Period of 10 years. Some of the interventions this Protocol certifies are delivered through capital assets with long investment horizons, which risk becoming stranded if eligibility requirements change before the investment is recovered. Others are delivered through changes to fuels, raw material inputs or operating practices on existing assets.
For the former, Projects may opt for a 15-year Crediting Period by demonstrating at Validation that:
[/R-2TDP-0]The Crediting Period is fixed at Validation and specified in the Project Design Document. A validated Project may issue EACs for the duration of its Crediting Period, subject to Issuance Review at each issuance request and to annual Surveillance Audits (Section 5.3). Together, these maintain integrity across the Crediting Period. At the end of the Crediting Period, the Project must be re-validated to continue issuing.
This section identifies the Buyer accounting frameworks under which a retired EAC issued under this Protocol is designed to be reported. Where a framework specifies how the EAC may be used, including substitution methods, matching rules, and any eligibility conditions, that framework's rules apply and the Protocol does not restate them.
An EAC issued under this Protocol is designed to be reportable under the major Buyer accounting frameworks. The framework a Beneficiary reports under determines how the EAC may be used and the entry it produces.
The Protocol's issuance-side integrity criteria are set at least as high as in SBTi V2.0, because that is the binding reference and imposes the strictest accounting criteria among the recognized frameworks. At a summary level:
Buyer reporting is the responsibility of the reporting party under the applicable framework's rules. Isometric does not audit downstream reporting. The Beneficiary should apply the current version of the framework in force at the time of retirement, and should verify that the framework has not been superseded by an updated version.
Additionally, where the Beneficiary uses the Retired EAC as the basis of an impact statement under a recognized framework, the Beneficiary is responsible for any leakage assessment required by that framework. This Protocol does not assess leakage at Issuance, and the Emission Reduction Value carried on the EAC reflects the certified product's cradle-to-gate GHG accounting boundary only.
This Risk of Reversal assessment applies to CCUS-backed EACs only. It determines the Project's Risk of Reversal category, which informs the monitoring program and the reversal treatment under Section 9.5 for closed-system storage, and for open-system storage, confirms the "No observable risk" category under which reversal risk is accounted for as the uncertainty discount in Section 9.2.1. The Risk of Reversal category is recorded as a Certificate Attribute under Appendix D.
The assessment is completed at Validation and reconfirmed at each Surveillance Audit, and is reassessed where monitoring identifies a reversal-related risk, the storage technology materially changes, or a Reversal occurs, per the Reversal and Buffer Pool sections of the Isometric Standard.
The Project Proponent first confirms whether the captured CO₂ is held in closed-system or open-system storage, as defined in Section 9.2, because this sets the reversal-accounting route. The Project then completes the assessment for the applicable storage system type below.
A CCUS-backed EAC Project should assess the following two factors under the Project-specific-factors question in the Standard's questionnaire, being the question that adds to the Risk Score where one or more Project-specific factors merit a higher risk level:
The assessment will inform the monitoring program and the reversal treatment under Section 9.5. Where a Project operates under a regulatory scheme recognized as equivalent under Section 5.6.4 of the Isometric Standard, reversal compensation is provided by that scheme per Section 9.5; the category is still assessed and recorded.
The Project's Risk of Reversal is "No observable risk", per Section 2.5.8 of the Isometric Standard, which assigns open-system storage to that category because direct observation of a Reversal is not feasible. The Project does not complete the closed-system assessment above.
For these pathways reversal risk is accounted for as the uncertainty discount set out in Section 9.2.1, which sources the discount, its 6% default, and the Project-specific reassessment procedure from Section 8 and Appendix A of Isometric's CO₂ Storage via Carbonation in the Built Environment Module.
The discount is 6% of the stored CO₂ at the 1,000-year Project Durability Threshold (Section 8.3 of the CO₂ Storage via Carbonation in the Built Environment Module). The mechanics by which the discount is applied to the Carbon Intensity carried on the EAC are set in Section 9.2.1.
This Appendix reproduces the country-level GCCA Low-Carbon Ratings Band C and Band B thresholds applicable under Section 7.3, stated in kg CO₂e per tonne of cement. The Band C column applies to output produced from 2025 to 2029 and the Band B column applies to output produced from 2030 onwards; the column that applies to a given quantity of certified output is set by its production vintage, per Section 7.3. Values are as of January 2026 and Isometric will update this Appendix in step with subsequent GCCA updates. The country list is not exhaustive and countries not listed should use the global row.
Country | Clinker-to-cement ratio | CCR source | Band C (2025 to 2029) | Band B (2030 onwards) |
|---|---|---|---|---|
Global | 0.750 | GNR global | 312 to 415 | 209 to 311 |
Argentina | 0.705 | GNR country-specific | 301 to 400 | 201 to 300 |
Austria | 0.689 | GNR country-specific | 297 to 394 | 198 to 296 |
Brazil | 0.710 | GNR country-specific | 302 to 401 | 202 to 301 |
Canada | 0.832 | GNR country-specific | 333 to 443 | 222 to 332 |
Colombia | 0.691 | GNR country-specific | 297 to 395 | 198 to 296 |
Czechia | 0.735 | GNR country-specific | 308 to 410 | 206 to 307 |
Egypt | 0.718 | GNR country-specific | 304 to 404 | 202 to 302 |
France | 0.768 | GNR country-specific | 317 to 421 | 212 to 316 |
Germany | 0.706 | Country-designated | 301 to 400 | 201 to 300 |
India | 0.713 | GNR country-specific | 303 to 402 | 202 to 302 |
Italy | 0.745 | GNR country-specific | 311 to 413 | 208 to 310 |
Philippines | 0.702 | GNR country-specific | 300 to 399 | 200 to 299 |
Poland | 0.731 | GNR country-specific | 307 to 409 | 205 to 306 |
Spain | 0.782 | GNR country-specific | 320 to 426 | 213 to 319 |
United Kingdom | 0.863 | GNR country-specific | 341 to 453 | 228 to 340 |
United States | 0.858 | GNR country-specific | 340 to 452 | 227 to 339 |
Values are stated in kg CO₂e per tonne of cement. Source: GCCA Low-Carbon Ratings for Cement and Concrete; country values reproduced from Book and Claim for Cement and Concrete Appendix C, January 20262726. Country-designated values apply where a country has adopted its own clinker-to-cement ratio applicable to the GCCA rating scheme.
This Appendix provides the conversion factors referenced in Section 11.2. The tables let a Beneficiary express a cement or concrete EAC in clinker-equivalent terms for internal comparison or portfolio reporting across Functional Units, where the framework under which the Beneficiary reports allows it.
A clinker-equivalent estimate must not be used for issuance, conversion under Section 11.2, or the emissions intensity threshold under Section 7.3.
One cement EAC is translated to clinker-equivalent tonnes by multiplying by the clinker-content factor of the declared cement type:
[math: CE_{Cement} = N_{EAC} \times f_{Clinker}]
Where:
Where the verified EPD for the certified product, or other producer-specific verified data, discloses the actual clinker content, the Beneficiary should use that value as [math: f_{Clinker}]. Where no such data are available, the Beneficiary should apply the default factor in Table C.1, being the upper limit of the clinker-content range that EN 197-1 Table 1 and EN 197-5 permit for the declared cement type. A clinker EAC translates at a factor of 1.00. The clinker-content ranges in EN 197-1 Table 1 and in EN 197-5 are expressed as the sum of the main and minor additional constituents, with calcium sulfate and additives additional to that sum. A default factor applied to an EAC, which is denominated in one metric tonne of finished cement, therefore overstates clinker content by the calcium sulfate and additive fraction. The default factors are retained on this basis for comparability with GCCA Rulebook A1.2.1.2827
Table C.1. Default clinker-content factors by cement type
Cement type (EN 197-1 and EN 197-5) | Permitted clinker content (percent by mass) | Default factor[math: f_{Clinker}] |
|---|---|---|
CEM I | 95 to 100 | 1.00 |
CEM II/A-S, A-P, A-Q, A-V, A-W, A-T, A-L, A-LL | 80 to 94 | 0.94 |
CEM II/A-D | 90 to 94 | 0.94 |
CEM II/A-M | 80 to 88 | 0.88 |
CEM II/B-S, B-P, B-Q, B-V, B-W, B-T, B-L, B-LL, B-M | 65 to 79 | 0.79 |
CEM II/C-M (EN 197-5) | 50 to 64 | 0.64 |
CEM III/A | 35 to 64 | 0.64 |
CEM III/B | 20 to 34 | 0.34 |
CEM III/C | 5 to 19 | 0.19 |
CEM IV/A | 65 to 89 | 0.89 |
CEM IV/B | 45 to 64 | 0.64 |
CEM V/A | 40 to 64 | 0.64 |
CEM V/B | 20 to 38 | 0.38 |
CEM VI (EN 197-5) | 35 to 49 | 0.49 |
For cement certified under a United States product standard, the default factor is derived as follows:
One concrete EAC is translated to clinker-equivalent tonnes in two steps, per GCCA Rulebook A1.2.2: the concrete volume is first translated to cement tonnage using a cement-content factor, and the resulting cement tonnage is translated to clinker-equivalent tonnes under the cement-to-clinker equivalence above.
A novel binder translates via its reference cement. The mass-equivalence factor assigned under Section 7.2.3, typically 1 to 1, converts the binder quantity to a quantity of the reference cement type, and Table C.1 then applies to that reference type, per GCCA Rulebook A1.2.3.
[math: CE_{Concrete} = N_{EAC} \times c \times f_{Clinker}]
Where:
Every concrete EAC issued under this Protocol carries a verified Environmental Product Declaration reference per Section 7.1, from which the cement content and cement type of the certified product are available. The Beneficiary should use those values for [math: c] and [math: f_{Clinker}].
Where the translation concerns a product with no verified Environmental Product Declaration, for example a conventional inventory line the Beneficiary is comparing against, the Beneficiary should derive the cement content from a cited regional industry-average concrete Environmental Product Declaration matched to the strength and exposure class of the comparison product. No global default table is provided at this time. GCCA Rulebook A1.2.2 anticipates the publication of standardized cement-content factors; when those factors are published, they supersede this Section.
A Novel Binder translates via its reference cement. The mass-equivalence factor assigned under Section 7.2.3, typically 1 to 1, converts the binder quantity to a quantity of the reference cement type, and Table C.1 then applies to that reference type, per GCCA Rulebook A1.2.3.
All EACs issued under this Protocol will carry the certificate metadata outlined in Section 5.1 of the Isometric Standard, as well as the cement-specific attributes set out below.
The cement-specific attributes are grouped by the requirement each field operationalizes2928. Cross-references indicate the Section that sets the substantive rule.
Product identity
Attribute | Protocol section |
|---|---|
Functional Unit (clinker, cement, or concrete) | 4 |
For cement: cement type class per EN 197-1, EN 197-5, or EN 197-6, or the equivalent ASTM classification and compressive strength class per EN 197-1 or the equivalent ASTM classification, including the early-strength designation (L, N or R) where EN 197-1 applies | 7.1 and 8.4.1 |
For concrete: product type (ready-mix, precast, or masonry), compressive strength class, and exposure class | 7.1 |
Country of production, and for concrete the sub-national region | 7.1 and 8.4 |
Production facility | 5.2 |
Carbon intensity and baseline
Attribute | Protocol section |
|---|---|
Certified product Carbon Intensity, in kg CO₂e per Functional Unit | 8.1 and 9.4 |
Carbon Intensity including stored biogenic CO₂, in kg CO₂e per Functional Unit, where reported. | 9.4 |
Baseline Carbon Intensity used for the Emission Reduction Value calculation, in kg CO₂e per Functional Unit and, for BL4, the lower and upper bounds of Band D | 8.4.1, 8.4.2 |
Baseline type (BL1 to BL4, per Table 2) | 8.4.1 |
Baseline source | 8.4 |
Baseline vintage | 8.4 |
Emission Reduction Value in kg CO₂e per Functional Unit, and, for BL4, the Emission Reduction Value calculated against each bound of Band D | 8.4.2, 8.4.3 |
GCCA Low-Carbon Rating band achieved (Near Zero, A, B, or C) for the country of production | 7.3 |
Pathway and lever
Attribute | Protocol section |
|---|---|
Decarbonization lever(s) (Carbon Capture and Storage (CCS), Carbon Capture and Utilization (CCU), | 7.2.1 |
Primary decarbonization lever, being the lever recorded under Decarbonization lever(s) that is the largest single contributor to the difference between the Carbon Intensity of the certified product and the Baseline. This must not be renewable electricity, low-carbon fuel procured through contractual instruments for grid-delivered supply, or a traditional SCM | 7.2.1 and 7.2.2 |
The type of each SCM in the certified product or, | 7.2.2 and 7.2.3 |
| 7.2.2 and 7.2.3 |
Contribution of each decarbonization lever to the Emission Reduction Value, in kg CO₂e per Functional Unit, and the residual from interaction between levers, where | 8.4.3 |
Additionality labels
Attribute | Protocol section |
|---|---|
Regulatory Additionality Category (Policy Free, Incentive Supported, Mandated Action, or Cap-and-Trade Coverage) | 5.5.4 |
Regulatory Surplus Evidence submitted for the declared category | 5.5.4 |
Enhanced Financial Additionality Declaration label, where | 5.5.3 |
Catalytic Impact
Attribute | Protocol section |
|---|---|
Catalytic Impact narrative | 7.4 |
CCUS-specific fields (for CCUS-backed EACs)
Attribute | Protocol section |
|---|---|
MRV protocol reference | 9.1 |
Storage operator identity | 9.7 |
Certificate of Storage reference, where submitted in lieu of the MRV protocol output | 9.1 |
Regulatory framework under which the storage site is permitted | 9.7 |
Project Durability Threshold | 9.2 |
Recognized equivalent regulatory scheme status, where applicable | 9.5 |
Stored biogenic CO₂ counted on the EAC, in kg CO₂ per Functional Unit, where applicable | 9.4 |
Stored biogenic CO₂ certified as a removal under the Bio-CCS Protocol for the Reporting Period, with the Removal Certificate reference, where applicable | 9.4 and 9.6 |
Open-system uncertainty discount applied to stored CO₂ certified within the reported Carbon Intensity, expressed as a fraction, where applicable | 9.2.1 |
Risk of Reversal category (closed-system category, or “No observable risk” for open-system storage) | 9.2 |
Lifecycle and verification
Attribute | Protocol section |
|---|---|
EPD reference: identifier, applicable PCR, and issue date | 7.1 and 8.2 |
EPD VVB identity and accreditation scope (including whether the accreditation covers the CCS add-on (Annex A of Smart EPD Part B 1000-017, or of 1000-010 v4.0 | 5.3 and 8.2 |
Validation date, Surveillance Audit date, and Reporting Period | 5.3, 11.1 and 11.5 |
Issuance date | 5.3 |
Production | 11.4 |
Date and evidence of the sale, shipment, or deployment against which the EAC was issued | 11.1 |
Double claiming and Physical Recipient
Attribute | Protocol section |
|---|---|
Reporting Period reference against which issuance has been reconciled to verified production | 10.1 |
Baseline value provided to the Physical Recipient, being the value the Physical Recipient reports | 10.1 and 10.2 |
Co-claiming
Attribute | Protocol section |
|---|---|
Retiring Account Holder and Beneficiary | 10.4 |
Co-claiming parties and their value-chain layer, where applicable | 10.4 |
The three Functional Units are functionally equivalent to the eligible functional units in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 2.1. The GCCA Chain of Custody Rulebook v1.0 Section 3.2 instead defines a single clinker-equivalent functional unit; the translation between the two is set in Appendix C. ↩
Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 2.1, states that no standard currently exists to establish a consistent replacement rate for an SCM in a verifiable or assurable manner. This Protocol adopts that position and routes SCMs through the cement and concrete Functional Units in the interim. GMA and RMI have indicated a potential update on direct issuance for SCM products. ↩
A product-type shift occurs where the certified product's product type differs from that of the product the facility produced before the intervention. Product type means the cement type class of the certified product under EN 197-1 or EN 197-5, or the equivalent classification under ASTM C150, C595, C1157 or another recognized product standard. For a novelNovel binderBinder the product type is the reference cement type assigned under that pathway. For concrete, product type means the product form (ready-mix, precast or masonry) together with the compressive strength class and exposure class. A change in the product standard or certification route under which an equivalent product is certified is not a product-type shift, provided the certified product meets the same strength and exposure classes as the pre-intervention product and substitutes for it in the same applications. ↩
This position was developed with reference to Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 3.3, which sets no formal financial additionality requirement and relies instead on procurement-side screening. This Protocol departs in offering an optional enhanced pathway under which Financial Additionality is demonstrated through Internal Rate of Return analysis. ↩
The Regulatory Surplus test, including its application at the entity and immediate supply chain level, is applied from AIM Platform Standard V1.0, Section 5.6 and Appendix G. The four Regulatory categories in Table 1, and the evidence requirements for each are applied directlyadapted from AIM Platform Standard V1.0, Appendix G. This Protocol does not restate or modify them. The disclosure-based structure is consistent with Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 3.2. The evidence required for each category is set by this Protocol. ↩
World Bank Group. (2022). Environmental, Health, and Safety Guidelines: Cement and Lime Manufacturing.https://www.ifc.org/content/dam/ifc/doc/2022/2022-cement-lime-manufacturing-ehs-guidelines-en.pdf↩
This treatment is functionally equivalent to the clinker intensity measurement approach in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 4.1. ↩
In concrete EPDs prepared under ISO 21930-based PCRs, the benefit of capturing CO₂ supplied from an external source is generally attributed to the facility where it was captured, under the allocation rules for recovered inputs. ↩
The exclusion of Enhanced Hydrocarbon Recovery is functionally equivalent to Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Sections 4.3 and 4.5, which bars Enhanced Oil Recovery from substantiating an emission reduction. This Protocol provides additional detail in permitting utilization pathways beyond mineralization where the Long-Term Storage definition in Section 9.2 is met, whereas that framework currently limits utilization to carbon mineralization. ↩
This exclusion was developed with reference to the qualitative primary-driver exclusion in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 3.3, which states that EACs should not be issued for blended cements or concretes where non-beneficiated or non-activated fly ash from coal-fired power plants or ground granulated blast-furnace slag represents the primary driver of emissions reductions relative to the appropriate baseline. This Protocol departs from that framework in two respects. It applies the exclusion to any cement or concrete, regardless of product standard or entry route. It also lifts the exclusion only where the traditional SCM has been Beneficiated, and not where it has been activated. This Protocol adds the Beneficiated and Activated definitions that set this boundary. ↩
The reference-cement equivalence route for novelNovel bindersBinders is applied directly from the GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0, Appendix A1.2.3. This Protocol adds the technical dossier and independent reviewer requirements that determine when equivalence is established. ↩
The band values are applied directly from the GCCA Low-Carbon Ratings for cement and concrete. This Protocol does not recalculate them. Anchoring the eligibility threshold to a GCCA band is functionally equivalent to Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 3.1. This Protocol departs in setting a scheduled tightening from Band C to Band B by production vintage. ↩
The Catalytic Impact narrative was developed with reference to the catalytic procurement guidance in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 3.3, which directs procurement toward products requiring additional revenue to reach commercialization. This Protocol departs in making the narrative a mandatory disclosure at Validation rather than Buyer-side guidance, to align with SBTi V2.0, and sets no absolute threshold. ↩
The Advance Market Commitment is described in Innovate UK Business Connect, Next-generation low-carbon concrete Advance Market Commitment. It is cited as an example only; this Protocol does not assess eligibility under the program. ↩
EPD International (2025) GENERAL PROGRAMME INSTRUCTIONS for the International EPD System Version 5.0.1 | Published on 2025-02-27. Available at: https://www.environdec.com/resources/general-programme-instructions↩
The CCS-specific accounting rules are applied directly from Smart EPD Part B v4.0, Product Category RulesPCR for ConstructionCementitious CementsMaterials Standard 1000-010017 v1.0, including theAnnex CCSA: add-onCarbon Capture, Utilization, and Storage. This Protocol does not restate or modify them. This follows Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Sections 4.3 and 4.4, in treating the captured CO2 as a deduction within the reported Carbon Intensity. The GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0 instead tracks stored CO2 in a separate ledger and adjusts the EPD value; this Protocol does not adopt that route. ↩
Gross accounting with no adjustment for emissions trading system allowances is functionally equivalent to the treatment in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 4, and in the GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0. ↩
The tiered Baseline selection structure was developed with reference to the accounting baseline approach in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 7, and to the carbon footprint calculation principles in the GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0, Appendix A1.1. This Protocol adds the treatment of multiple interventions within one Project, and sets its own evidence requirement for each row. This Protocol does not adopt the rule in Section 7.1 of that framework that sets the Baseline for a product not previously produced at an existing facility from the products it replaces. Under this Protocol, such a Project uses the approved benchmark for the product it now produces (BL3), or the GCCA Band D fallback (BL4). This is the more conservative position, and the approach will be reviewed for a future version. ↩
The principle that the Baseline is updated over time, and that the cadence follows existing industry cycles rather than a fixed period, was developed with reference to Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 7. For BL1, this Protocol ties the update cadence to the EPD sensitivity check at Surveillance Audit. ↩
Emission Reduction Value is functionally equivalent to the intervention outcome in AIM Platform Standard V1.0. The two terms describe the same quantity and a Beneficiary reporting under that Standard may use the Emission Reduction Value carried on the EAC without adjustment. ↩
The monitoring report is the periodic report the storage operator produces by applying the applicable MRV protocol, not the ProtocolMRV protocol itself. Where the storage site is permitted under the EU CCS Directive (Directive 2009/31/EC), this is the report the operator submits to the competent authority under Article 14, covering the monitoring results required by Annex II. Where the site reports under the United States Greenhouse Gas Reporting Program, this is the annual report submitted under 40 CFR Part 98 Subpart RR against an EPA-approved MRV plan. Where neither applies, it is the equivalent report prepared under the MRV protocol referenced at Validation. ↩↩2
The Certificate of Storage is defined in the GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0, Section 2.4. This Protocol does not require a Certificate of Storage but accepts one in lieu of a separate MRV protocol output, so that a producer already transacting under that Rulebook is not required to produce a second document. ↩
The conveyance requirements are functionally equivalent to Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Sections 8.1 and 8.2, which use the same three channels: the EPD notes field, a cover page, and a status flag in the EPD database. A producer transacting under both frameworks satisfies one set of requirements. ↩
This prohibition is functionally equivalent to Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 5.2, which requires that EACs are tracked on a digital registry and are not issued simultaneously on multiple registries. ↩
The value-chain layer structure was developed with reference to the co-claiming provisions in the GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0, Section 4.2, and in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 6.4. This Protocol defines each layer by accounting relationship rather than entity type, and adds the within-layer election rule. ↩
The issuance trigger is functionally equivalent to Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 5.1. ↩
The country-level values in this Appendix are reproduced from Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Appendix C, which derives them from the GCCA Low-Carbon Ratings using country-specific clinker-to-cement ratios. This Protocol applies those values directly and does not recalculate them. Reproduced under CC BY-SA 4.0, https://creativecommons.org/licenses/by-sa/4.0/. ↩
The equivalence methodology in this Appendix is applied directly from the GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0, Appendix A1.2: cement-to-clinker per A1.2.1, concrete-to-clinker per A1.2.2, and novelNovel bindersBinders per A1.2.3. This Protocol does not modify the methodology. The default clinker-content factors in Table C.1 are derived from the clinker-content ranges in EN 197-1 Table 1 and EN 197-5, applying the upper limit as the default consistent with A1.2.1. ↩
The cement-specific attribute set was developed with reference to the registry tracking requirements in Book and Claim for Cement and Concrete, Center for Green Market Activation and RMI, 2026, Section 5.2.2, and to the certificate data requirements in the GCCA Cement and Concrete Industry Chain of Custody Rulebook v1.0, Section 4.2. This Protocol carries additional fields required by its own rules, including SCM contribution percentage, the Regulatory Additionality Category, and the open-system uncertainty discount. ↩