Credits issued1,000Y+
7.02 tCO₂e removal by Vaulted Deep
Removal details
Supplier
Tonnes removed
7.02 tCO₂e
Sequestration date
20 Dec 2023
Reporting period
17 Nov 2023 to 15 Mar 2024
Removal method
Calculation view
Datapoints
| Name | Value | Collection method | Sources | 
|---|---|---|---|
| Mass of waste biomass | 22.090 t | Reported | Evidence bundle for load 7769 | 
| Carbon concentration | 0.089650 | Derived | — | 
| CO₂e eq mass of C | 3.666667 | Constant | — | 
| Final office meter reading | 59,539.00 kWh | Reported | Evidence bundle for load 7769 | 
| Initial office meter reading | 59,532.00 kWh | Reported | Evidence bundle for load 7769 | 
| Grid emissions factor | 0.52 kgCO₂e/kWh | Standard Published Value | Grid emissions factor | 
| Processing & Injection energy use | 120.00 kWh | Reported | Evidence bundle for load 7769 | 
| Attribution factor | N/A | Derived | — | 
| Mass of steel used in facility | 70.313 t | Derived | — | 
| Steel production emissions factor | 5.13 kgCO₂e/kg | Standard Published Value | Steel production emissions factor | 
| Steel scrapping emissions factor | 0.01 kgCO₂e/kg | Standard Published Value | Steel scrapping emissions factor | 
| Volume of concrete used in facility | 153.10 m³ | Derived | — | 
| Concrete emissions factor | 366.56 kg/m³ | Standard Published Value | Concrete emissions factor | 
| Pump embodied emissions factor | 0.01 kgCO₂e/MJ | Standard Published Value | Pump embodied emissions factor | 
| Biomass transport distance | 61.16 km | Reported | Biomass transport distance | 
| Diesel emissions factor | 3,442.99 kg/m³ | Standard Published Value | — | 
| Empty truck MPG | 7.00 mi/gal | Standard Published Value | Empty truck MPG | 
| Fully loaded truck MPG | 5.50 mi/gal | Standard Published Value | Fully loaded truck MPG | 
| Front loader diesel consumption | <0.01 m³ | Reported | Evidence bundle for load 7769 |