Credits issued1,000Y+
6.53 tCO₂e removal by Vaulted Deep
Removal details
Supplier
Tonnes removed
6.53 tCO₂e
Sequestration date
29 Dec 2023
Removal method
Calculation view
Data points
Data points (18)
Name | Value | Collection method | Sources |
---|---|---|---|
Mass of waste biomass | 20.983 t | Reported | Evidence bundle for load 7797 |
Carbon concentration | 0.089131 | Derived | — |
CO₂e eq mass of C | 3.666667 | Constant | — |
Biomass transport distance | 61.16 km | Reported | Biomass transport distance |
Diesel emissions factor | 3,442.99 kg/m³ | Standard Published Value | — |
Empty truck MPG | 4.50 mi/gal | Standard Published Value | Empty truck MPG |
Fully loaded truck MPG | 3.50 mi/gal | Standard Published Value | Fully loaded truck MPG |
Final office meter reading | 55,096.00 kWh | Reported | Evidence bundle for load 7797 |
Initial office meter reading | 55,093.00 kWh | Reported | Evidence bundle for load 7797 |
Grid emissions factor | 0.52 kgCO₂e/kWh | Standard Published Value | Grid emissions factor |
Processing & Injection energy use | 120.00 kWh | Reported | Evidence bundle for load 7797 |
Attribution factor | <0.01 % | Derived | — |
Mass of steel used in facility | 70.313 t | Derived | — |
Steel production emissions factor | 5.13 kgCO₂e/kg | Standard Published Value | Steel production emissions factor |
Steel scrapping emissions factor | 0.01 kgCO₂e/kg | Standard Published Value | Steel scrapping emissions factor |
Volume of concrete used in facility | 153.10 m³ | Derived | — |
Concrete emissions factor | 366.56 kg/m³ | Standard Published Value | Concrete emissions factor |
Pump embodied emissions factor | 0.01 kgCO₂e/MJ | Standard Published Value | Pump embodied emissions factor |