Credits issued1,000Y+
6.46 tCO₂e removal by Vaulted Deep
Removal details
Supplier
Tonnes removed
6.46 tCO₂e
Sequestration date
18 Mar 2024
Reporting period
16 Mar 2024 to 31 May 2024
Removal method
Calculation view
Data points
Data points (24)
Name | Value | Collection method | Sources |
---|---|---|---|
Final office meter reading | 67,448.00 kWh | Reported | Tonnage Evidence |
Initial office meter reading | 67,444.00 kWh | Reported | Tonnage Evidence |
Office Energy Consumption | 4.00 kWh | Derived | Tonnage Evidence |
Pump embodied emissions factor | 0.01 kgCO₂e/MJ | Standard Published Value | — |
Grid emissions factor | 0.52 kgCO₂e/kWh | Standard Published Value | — |
Mass of steel used in facility | 70.313 t | Derived | — |
Steel scrapping emissions factor | 0.01 kgCO₂e/kg | Standard Published Value | — |
Steel production emissions factor | 5.13 kgCO₂e/kg | Standard Published Value | — |
Processing & Injection energy use | 120.00 kWh | Reported | Tonnage Evidence |
Volume of concrete used in facility | 367.428 t | Derived | — |
Concrete emissions factor | 152.73 kgCO₂e/t | Standard Published Value | — |
Mass of lab samples | 0 kg | Derived | — |
Distance to lab | 490.85 km | Standard Published Value | — |
lab sampling truck emissions factor | 0.24 kgCO₂e/km/t | Standard Published Value | — |
Fully loaded truck MPG | 4.00 mi/gal | Standard Published Value | — |
Biomass transport distance | 61.16 km | Reported | Biomass transport distance |
Diesel emissions factor | 3,442.99 kg/m³ | Standard Published Value | — |
Empty truck MPG | 5.00 mi/gal | Standard Published Value | — |
Front loader diesel consumption | 0 kg | Reported | — |
Carbon intensity of combustion | 4.05 kgCO₂e/kg | Standard Published Value | — |
Attribution factor | <0.01 % | Standard Published Value | — |
Mass of waste biomass | 20.484 t | Reported | Tonnage Evidence |
CO2e eq mass of C | 3.666667 | Constant | — |
Estimated carbon content of injectant | Multiple values | — | 168 measurements |