Credits issued1,000Y+

7.26 tCO₂e removal by Vaulted Deep

rmv_1J0B2WPHB1S0Y31N

Removal details

Supplier
Tonnes removed
7.26 tCO₂e
Sequestration date
17 May 2024
Reporting period
16 Mar 2024 to 31 May 2024

Verification details

Version
v1.1
Verifier

Data points (24)

NameValueCollection methodSources
Mass of waste biomass24.013 tReportedTonnage Evidence
CO2e eq mass of C3.666667 Constant
Front loader diesel consumption0 kgReported
Carbon intensity of combustion4.05 kgCO₂e/kgStandard Published Value
Biomass transport distance61.16 kmReportedBiomass transport distance
Diesel emissions factor3,442.99 kg/m³Standard Published Value
Empty truck MPG6.00 mi/galStandard Published Value
Fully loaded truck MPG5.00 mi/galStandard Published Value
Mass of lab samples0 kgDerived
Distance to lab490.85 kmStandard Published Value
lab sampling truck emissions factor0.24 kgCO₂e/(km⋅t)Standard Published Value
Attribution factor<0.01 %Standard Published Value
Volume of concrete used in facility367.428 tDerived
Concrete emissions factor152.73 kgCO₂e/tStandard Published Value
Processing & Injection energy use80.00 kWhReportedTonnage Evidence
Pump embodied emissions factor0.01 kgCO₂e/MJStandard Published Value
Mass of steel used in facility70.313 tDerived
Steel production emissions factor5.13 kgCO₂e/kgStandard Published Value
Steel scrapping emissions factor0.01 kgCO₂e/kgStandard Published Value
Final office meter reading72,450.00 kWhReportedTonnage Evidence
Initial office meter reading72,440.00 kWhReportedTonnage Evidence
Grid emissions factor0.52 kgCO₂e/kWhStandard Published Value
Office Energy Consumption10.00 kWhDerivedTonnage Evidence
Estimated carbon content of injectantMultiple values 66 measurements