Credits issued1,000Y+
7.10 tCO₂e removal by Vaulted Deep
Removal details
Supplier
Tonnes removed
7.10 tCO₂e
Sequestration date
31 May 2024
Reporting period
16 Mar 2024 to 31 May 2024
Removal method
Calculation view
Datapoints
| Name | Value | Collection method | Sources |
|---|---|---|---|
| Final office meter reading | 73,977.00 kWh | Reported | Tonnage Evidence |
| Initial office meter reading | 73,969.00 kWh | Reported | Tonnage Evidence |
| Office Energy Consumption | 8.00 kWh | Derived | Tonnage Evidence |
| Pump embodied emissions factor | 0.01 kgCO₂e/MJ | Standard Published Value | — |
| Grid emissions factor | 0.52 kgCO₂e/kWh | Standard Published Value | — |
| Mass of steel used in facility | 70.313 t | Derived | — |
| Steel scrapping emissions factor | 0.01 kgCO₂e/kg | Standard Published Value | — |
| Steel production emissions factor | 5.13 kgCO₂e/kg | Standard Published Value | — |
| Processing & Injection energy use | 120.00 kWh | Reported | Tonnage Evidence |
| Volume of concrete used in facility | 367.428 t | Derived | — |
| Concrete emissions factor | 152.73 kgCO₂e/t | Standard Published Value | — |
| Mass of lab samples | 0 kg | Derived | — |
| Distance to lab | 490.85 km | Standard Published Value | — |
| lab sampling truck emissions factor | 0.24 kgCO₂e/(km⋅t) | Standard Published Value | — |
| Fully loaded truck MPG | 6.00 mi/gal | Standard Published Value | — |
| Biomass transport distance | 61.16 km | Reported | Biomass transport distance |
| Diesel emissions factor | 3,442.99 kg/m³ | Standard Published Value | — |
| Empty truck MPG | 8.00 mi/gal | Standard Published Value | — |
| Front loader diesel consumption | 0 kg | Reported | — |
| Carbon intensity of combustion | 4.05 kgCO₂e/kg | Standard Published Value | — |
| Attribution factor | N/A | Standard Published Value | — |
| Mass of waste biomass | 23.614 t | Reported | Tonnage Evidence |
| CO2e eq mass of C | 3.666667 | Constant | — |
| Estimated carbon content of injectant | Multiple values | — | 78 measurements |