Credits issued1,000Y+

6.93 tCO₂e removal by Vaulted Deep

rmv_1J80NXCHP1S0WGNG

Removal details

Supplier
Tonnes removed
6.93 tCO₂e
Sequestration date
03 Sep 2024
Reporting period
01 Aug 2024 to 07 Sep 2024

Verification details

Version
v1.1
Verifier

Data points (24)

NameValueCollection methodSources
Mass of waste biomass18.126 tReported
CO2e eq mass of C3.666667 Constant
Front loader diesel consumption23 kgReported
Carbon intensity of combustion4.05 kgCO₂e/kgStandard Published Value
Biomass transport distance85.30 kmReportedDistance from feedstock source to processing site
Diesel emissions factor3,442.99 kg/m³Standard Published Value
Empty truck MPG6.25 mi/galStandard Published Value
Fully loaded truck MPG5.00 mi/galStandard Published Value
Mass of lab samples1 kgDerivedSample Weight Pratt Feeders Manure
Distance to lab490.85 kmStandard Published Value
lab sampling truck emissions factor0.24 kgCO₂e/km/tStandard Published Value
Attribution factor<0.01 %Standard Published Value
Volume of concrete used in facility367.428 tDerived
Concrete emissions factor152.73 kgCO₂e/tStandard Published Value
Processing & Injection energy use80.00 kWhReportedFinal Process Energy Use
Pump embodied emissions factor0.01 kgCO₂e/MJStandard Published Value
Mass of steel used in facility100.369 tDerivedMass Steel Mp2 Horizontal Ginder
Steel production emissions factor5.13 kgCO₂e/kgStandard Published Value
Steel scrapping emissions factor0.01 kgCO₂e/kgStandard Published Value
Office Energy Consumption3.00 kWhDerivedFinal Office Meter Readout
Grid emissions factor0.52 kgCO₂e/kWhStandard Published Value
Replacement Emission0.00 kgCO₂e/tStandard Published Value2024-08 [Vaulted] [Derby] Replacement Emissions for Biosolids
Carbon content measurements of injectantMultiple values 3 measurements
Historical carbon content measurements of injectantMultiple values 12 measurements
6.93 tCO₂e removal by Vaulted Deep — Isometric — Isometric