Credits issued1,000Y+
5.44 tCO₂e removal by Vaulted Deep
Removal details
Supplier
Tonnes removed
5.44 tCO₂e
Sequestration date
10 Oct 2024
Reporting period
01 Oct 2024 to 31 Oct 2024
Removal method
Calculation view
Datapoints
| Name | Value | Collection method | Sources |
|---|---|---|---|
| Mass of waste biomass | 20.448 t | Reported | Tonnage Evidence |
| CO2e eq mass of C | 3.666667 | Constant | — |
| Front loader diesel consumption | 19 kg | Reported | — |
| Carbon intensity of combustion | 4.05 kgCO₂e/kg | Standard Published Value | — |
| Screening Time | 1 kg | Derived | — |
| Trommel Carbon intensity of combustion | 18.77 kgCO₂e/kg | Standard Published Value | — |
| Screening Front loader diesel consumption | 6 kg | Reported | — |
| Biomass transport distance | 103.00 km | Reported | — |
| Diesel emissions factor | 3,442.99 kg/m³ | Standard Published Value | — |
| Empty truck MPG | 6.00 mi/gal | Standard Published Value | — |
| Fully loaded truck MPG | 5.00 mi/gal | Standard Published Value | — |
| Mass of lab samples | 1 kg | Derived | 4S Manure Sample Weight |
| Distance to lab | 490.85 km | Standard Published Value | — |
| lab sampling truck emissions factor | 0.24 kgCO₂e/(km⋅t) | Standard Published Value | — |
| Attribution factor | <0.01% | Standard Published Value | — |
| Volume of concrete used in facility | 367.428 t | Derived | — |
| Concrete emissions factor | 152.73 kgCO₂e/t | Standard Published Value | — |
| Processing & Injection energy use | 120.00 kWh | Reported | Tonnage Evidence |
| Pump embodied emissions factor | 0.01 kgCO₂e/MJ | Standard Published Value | — |
| Mass of steel used in facility | 100.369 t | Derived | Mass Steel Mp2 Horizontal Ginder |
| Steel production emissions factor | 5.13 kgCO₂e/kg | Standard Published Value | — |
| Steel scrapping emissions factor | 0.01 kgCO₂e/kg | Standard Published Value | — |
| Office Energy Consumption | 2.00 kWh | Derived | Tonnage Evidence |
| Grid emissions factor | 0.52 kgCO₂e/kWh | Standard Published Value | — |
| Replacement Emission | 0 kgCO₂e/t | Standard Published Value | 2024-08 [Vaulted] [Derby] Replacement Emissions for Biosolids |
| Carbon content measurements of injectant | Multiple values | — | 3 measurements |
| Historical carbon content measurements of injectant | Multiple values | — | 72 measurements |