Credits issued1,000Y+

9.13 tCO₂e removal by Vaulted Deep

rmv_1JE9VWZNJ1S0T5RE

Removal details

Supplier
Tonnes removed
9.13 tCO₂e
Sequestration date
15 Nov 2024 to 19 Nov 2024
Reporting period
01 Nov 2024 to 30 Nov 2024

Verification details

Version
v1.1
Verifier

Datapoints (42)

NameValueCollection methodSources
Attribution factor100%Reported
Mass of waste biomass27.896 tReportedTonnage Evidence
CO2e eq mass of C3.666667 Constant
Attribution factor100%Reported
Front loader diesel consumption19 kgReported
Carbon intensity of combustion4.05 kgCO₂e/kgStandard Published Value
Attribution factor100%Reported
Screening Time1 kgDerived
Trommel Carbon intensity of combustion18.77 kgCO₂e/kgStandard Published Value
Attribution factor100%Reported
Screening Front loader diesel consumption6 kgReported
Attribution factor100%Reported
Biomass transport distance85.30 kmReportedDistance from feedstock source to processing site
Diesel emissions factor3,442.99 kg/m³Standard Published Value
Empty truck MPG6.90 mi/galStandard Published Value
Attribution factor100%Reported
Fully loaded truck MPG5.30 mi/galStandard Published Value
Attribution factor100%Reported
Mass of lab samples0 kgDerived
Distance to lab490.85 kmStandard Published Value
lab sampling truck emissions factor0.24 kgCO₂e/(km⋅t)Standard Published Value
Attribution factor0%Standard Published Value
Volume of concrete used in facility367.428 tDerived
Concrete emissions factor152.73 kgCO₂e/tStandard Published Value
Attribution factor100%Reported
Processing & Injection energy use120.00 kWhReportedFinal Process Energy Use
Pump embodied emissions factor0.01 kgCO₂e/MJStandard Published Value
Mass of steel used in facility100.369 tDerivedMass Steel Mp2 Horizontal Ginder
Steel production emissions factor5.13 kgCO₂e/kgStandard Published Value
Steel scrapping emissions factor0.01 kgCO₂e/kgStandard Published Value
Attribution factor100%Reported
Office Energy Consumption2.00 kWhDerivedFinal Office Meter Readout
Grid emissions factor0.52 kgCO₂e/kWhStandard Published Value
Attribution factor100%Reported
Attribution factor100%Reported
Attribution factor100%Reported
Attribution factor100%Reported
Attribution factor100%Reported
Attribution factor100%Reported
Attribution factor100%Reported
Replacement Emission0.00 kgCO₂e/tStandard Published Value2024-08 [Vaulted] [Derby] Replacement Emissions for Biosolids
Estimated carbon content of injectantMultiple values 150 measurements
9.13 tCO₂e removal by Vaulted Deep — Isometric — Isometric