Credits issued1,000Y+
5.04 tCO₂e removal by Charm Industrial
Removal details
Supplier
Tonnes removed
5.04 tCO₂e
Sequestration date
12 Mar 2024
Removal method
Calculation view
Data points
Data points (90)
Name | Value | Collection method | Sources |
---|---|---|---|
Attribution factor for Removal 727, Lot 740 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1149: verified mass for lot 740 | 18.301 t | Reported | verified mass for lot 740 |
Measurement 1150: carbon content for removal 727 | 0.448300 | Reported | carbon content for removal 727 |
Removal 727 CO2/C ratio | 3.664141 | Constant | — |
Attribution factor for Removal 727, Lot 727 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1137: verified mass for lot 727 | 20.070 t | Reported | verified mass for lot 727 |
AECN Pyrolysis Process Emissions (Stack-Inclusive) | 89.40 kgCO₂e/t | Standard Published Value | AECN Pyrolysis Process Emissions (Stack-Inclusive) |
AECN Pyrolysis Embodied Emissions emission factor | 21.16 kgCO₂e/t | Standard Published Value | AECN Pyrolysis Embodied Emissions |
Attribution factor for Removal 727, Lot 738 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1135: Transwood OK to Minifinery to Va | 374.98 km | Reported | Transwood OK to Minifinery to Vaulted |
Tanker Truck Transport Embodied Emissions (Deadhea | 0.0477 kgCO₂e/km | Standard Published Value | Tanker Truck Transport Embodied Emissions (Deadhea |
Measurement 1123: AECN to Minifinery Trucking Dist | 3,267.00 km | Reported | AECN to Minifinery Trucking Distance |
Tanker Truck Transport Process Emissions emission | 0.08 kgCO₂e/km/t | Standard Published Value | Tanker Truck Transport Process Emissions |
Attribution factor for Removal 727, Lot 739 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1147: verified mass for lot 739 | 11.947 t | Reported | verified mass for lot 739 |
Measurement 1146: verified mass for lot 738 | 9.416 t | Reported | verified mass for lot 738 |
Attribution factor for Removal 727, Lot 731 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1148: LCS used for lot 731 | 0.83 m³ | Reported | LCS used for lot 731 |
Liquid Caustic Soda (LCS) Embodied Emissions emiss | 1,540.65 kg/m³ | Standard Published Value | Liquid Caustic Soda (LCS) Embodied Emissions |
Samples for Injection Batch MRV emission factor | 4 kg | Standard Published Value | Samples for Injection Batch MRV |
Attribution factor for Site Emission offset 9 | 100.00 % | Derived | — |
Measurement 1157: mass for diesel delivery at site | 1.578 t | Reported | mass for diesel delivery at site 34 (AJ's) at 2024 |
Diesel Fuel Combustion emission factor | 3.89 kgCO₂e/kg | Standard Published Value | Diesel Fuel Combustion |
Attribution factor for Site Emission offset 10 | 100.00 % | Derived | — |
Measurement 1130: Minifinery to Security Oil Truck | 4.67 km | Reported | Minifinery to Security Oil Trucking Distance Measu |
Flatbed Truck Transport Process Emissions emission | 0.14 kg/t/mi | Standard Published Value | Flatbed Truck Transport Process Emissions |
Attribution factor for Site Emission offset 11 | 100.00 % | Derived | — |
Flatbed Truck Transport Embodied Emissions emissio | 0.0390 kgCO₂e/km | Standard Published Value | Flatbed truck embodied emissions |
Attribution factor for Site Emission offset 12 | 100.00 % | Derived | — |
Measurement 1158: mass for diesel delivery at site | 982 kg | Reported | mass for diesel delivery at site 34 (AJ's) at 2024 |
Attribution factor for Site Emission offset 13 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 14 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 15 | 100.00 % | Derived | — |
Measurement 1159: mass for diesel delivery at site | 911 kg | Reported | mass for diesel delivery at site 34 (AJ's) at 2024 |
Attribution factor for Site Emission offset 16 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 17 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 18 | 100.00 % | Derived | — |
Measurement 1160: mass for LCS delivery at site 34 | 1.542 t | Reported | mass for LCS delivery at site 34 (AJ's) at 2024-03 |
Measurement 1128: El Dorado to Univar Solutoins Tr | 53.91 km | Reported | El Dorado to Univar Solutoins Truck Route |
Attribution factor for Site Emission offset 19 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 20 | 100.00 % | Derived | — |
Measurement 1161: mass for LCS delivery at site 34 | 1.542 t | Reported | mass for LCS delivery at site 34 (AJ's) at 2024-03 |
Attribution factor for Site Emission offset 21 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 22 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 23 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 24 | 100.00 % | Derived | — |
Measurement 1133: electricity use at site 1 (advan | 248.00 kWh | Reported | electricity use at site 1 (advantek sw 12) reporte |
KS Grid Electricity Emissions emission factor | 0.46 kgCO₂e/kWh | Standard Published Value | KS Grid Electricity Emissions |
Attribution factor for Site Emission offset 25 | 100.00 % | Derived | — |
Measurement 1136: mass for salt delivery at site 3 | 7.739 t | Reported | mass for salt delivery at site 34 (AJ's) at 2024-0 |
Measurement 1134: Morton factory to Vaulted to Min | 112.01 km | Reported | Morton factory to Vaulted to Minifinery Facility |
Attribution factor for Site Emission offset 26 | 100.00 % | Derived | — |
Attribution factor for Embodied Emission offset 20 | 1.32 % | Derived | — |
Embodied Emission 1: Auger System | 302 kg | Reported | embodied emissions for equipment "Auger System" at |
Attribution factor for Embodied Emission offset 21 | 1.53 % | Derived | — |
Embodied Emission 2: Tank Plumbing and Manifold Sy | 1.311 t | Reported | embodied emissions for equipment "Tank Plumbing an |
Attribution factor for Embodied Emission offset 22 | 1.50 % | Derived | — |
Embodied Emission 3: Sparge Tank 1 | 1.068 t | Reported | embodied emissions for equipment "Sparge Tank 1" a |
Attribution factor for Embodied Emission offset 23 | 1.50 % | Derived | — |
Embodied Emission 4: Blend Tank A | 1.068 t | Reported | embodied emissions for equipment "Blend Tank A" at |
Attribution factor for Embodied Emission offset 24 | 1.56 % | Derived | — |
Embodied Emission 5: MCM Pump 1 | 2.496 t | Reported | embodied emissions for equipment "MCM Pump 1" at s |
Attribution factor for Embodied Emission offset 25 | 1.56 % | Derived | — |
Embodied Emission 6: MCM Pump 2 | 2.496 t | Reported | embodied emissions for equipment "MCM Pump 2" at s |
Attribution factor for Embodied Emission offset 26 | 1.56 % | Derived | — |
Embodied Emission 7: MCM Pump 3 | 2.496 t | Reported | embodied emissions for equipment "MCM Pump 3" at s |
Attribution factor for Embodied Emission offset 27 | 1.59 % | Derived | — |
Embodied Emission 8: Sparging System Air Compresso | 3.970 t | Reported | embodied emissions for equipment "Sparging System |
Attribution factor for Embodied Emission offset 28 | 1.98 % | Derived | — |
Embodied Emission 9: Caterpillar XQ200 - Primary F | 19.970 t | Reported | embodied emissions for equipment "Caterpillar XQ20 |
Attribution factor for Embodied Emission offset 29 | 0.50 % | Derived | — |
Embodied Emission 10: Caterpillar XQ200 -- Chiller | 19.970 t | Reported | embodied emissions for equipment "Caterpillar XQ20 |
Attribution factor for Embodied Emission offset 30 | 0.63 % | Derived | — |
Embodied Emission 14: Thermal Oxidizer | 15.490 t | Reported | embodied emissions for equipment "Thermal Oxidizer |
Attribution factor for Embodied Emission offset 31 | 0.41 % | Derived | — |
Embodied Emission 16: CAT TL1055D | 32.120 t | Reported | embodied emissions for equipment "CAT TL1055D" at |
Attribution factor for Embodied Emission offset 32 | 0.41 % | Derived | — |
Embodied Emission 17: CAT 289D3 | 18.920 t | Reported | embodied emissions for equipment "CAT 289D3" at si |
Attribution factor for Embodied Emission offset 33 | 0.52 % | Derived | — |
Embodied Emission 18: Genie S-45 XC | 24.140 t | Reported | embodied emissions for equipment "Genie S-45 XC" a |
Attribution factor for Embodied Emission offset 34 | 3.96 % | Derived | — |
Embodied Emission 19: Re-Bar Reinforced Concrete P | 7.249 t | Reported | embodied emissions for equipment "Re-Bar Reinforce |
Attribution factor for Embodied Emission offset 35 | 0.40 % | Derived | — |
Embodied Emission 20: LCS Chiller | 14.160 t | Reported | embodied emissions for equipment "LCS Chiller" at |
Attribution factor for Embodied Emission offset 36 | 2.15 % | Derived | — |
Embodied Emission 11: Light Tower Generator 1 | 1.910 t | Reported | embodied emissions for equipment "Light Tower Gene |
Attribution factor for Embodied Emission offset 37 | 2.15 % | Derived | — |
Embodied Emission 12: Light Tower Generator 2 | 1.910 t | Reported | embodied emissions for equipment "Light Tower Gene |
Attribution factor for Embodied Emission offset 38 | 2.15 % | Derived | — |
Embodied Emission 13: Light Tower Generator 3 | 1.910 t | Reported | embodied emissions for equipment "Light Tower Gene |