Credits issued1,000Y+

5.04 tCO₂e removal by Charm Industrial

rmv_1J09YQ0921S0WAQD

Removal details

Tonnes removed
5.04 tCO₂e
Sequestration date
12 Mar 2024

Verification details

Version
v1.1
Verifier

Data points (90)

NameValueCollection methodSources
Attribution factor for Removal 727, Lot 740100.00 %DerivedLot and transfer graph for Removal 727
Measurement 1149: verified mass for lot 74018.301 tReportedverified mass for lot 740
Measurement 1150: carbon content for removal 7270.448300 Reportedcarbon content for removal 727
Removal 727 CO2/C ratio3.664141 Constant
Attribution factor for Removal 727, Lot 727100.00 %DerivedLot and transfer graph for Removal 727
Measurement 1137: verified mass for lot 72720.070 tReportedverified mass for lot 727
AECN Pyrolysis Process Emissions (Stack-Inclusive)89.40 kgCO₂e/tStandard Published ValueAECN Pyrolysis Process Emissions (Stack-Inclusive)
AECN Pyrolysis Embodied Emissions emission factor21.16 kgCO₂e/tStandard Published ValueAECN Pyrolysis Embodied Emissions
Attribution factor for Removal 727, Lot 738100.00 %DerivedLot and transfer graph for Removal 727
Measurement 1135: Transwood OK to Minifinery to Va374.98 kmReportedTranswood OK to Minifinery to Vaulted
Tanker Truck Transport Embodied Emissions (Deadhea0.0477 kgCO₂e/kmStandard Published ValueTanker Truck Transport Embodied Emissions (Deadhea
Measurement 1123: AECN to Minifinery Trucking Dist3,267.00 kmReportedAECN to Minifinery Trucking Distance
Tanker Truck Transport Process Emissions emission 0.08 kgCO₂e/km/tStandard Published ValueTanker Truck Transport Process Emissions
Attribution factor for Removal 727, Lot 739100.00 %DerivedLot and transfer graph for Removal 727
Measurement 1147: verified mass for lot 73911.947 tReportedverified mass for lot 739
Measurement 1146: verified mass for lot 7389.416 tReportedverified mass for lot 738
Attribution factor for Removal 727, Lot 731100.00 %DerivedLot and transfer graph for Removal 727
Measurement 1148: LCS used for lot 7310.83 m³ReportedLCS used for lot 731
Liquid Caustic Soda (LCS) Embodied Emissions emiss1,540.65 kg/m³Standard Published ValueLiquid Caustic Soda (LCS) Embodied Emissions
Samples for Injection Batch MRV emission factor4 kgStandard Published ValueSamples for Injection Batch MRV
Attribution factor for Site Emission offset 9100.00 %Derived
Measurement 1157: mass for diesel delivery at site1.578 tReportedmass for diesel delivery at site 34 (AJ's) at 2024
Diesel Fuel Combustion emission factor3.89 kgCO₂e/kgStandard Published ValueDiesel Fuel Combustion
Attribution factor for Site Emission offset 10100.00 %Derived
Measurement 1130: Minifinery to Security Oil Truck4.67 kmReportedMinifinery to Security Oil Trucking Distance Measu
Flatbed Truck Transport Process Emissions emission0.14 kg/t/miStandard Published ValueFlatbed Truck Transport Process Emissions
Attribution factor for Site Emission offset 11100.00 %Derived
Flatbed Truck Transport Embodied Emissions emissio0.0390 kgCO₂e/kmStandard Published ValueFlatbed truck embodied emissions
Attribution factor for Site Emission offset 12100.00 %Derived
Measurement 1158: mass for diesel delivery at site982 kgReportedmass for diesel delivery at site 34 (AJ's) at 2024
Attribution factor for Site Emission offset 13100.00 %Derived
Attribution factor for Site Emission offset 14100.00 %Derived
Attribution factor for Site Emission offset 15100.00 %Derived
Measurement 1159: mass for diesel delivery at site911 kgReportedmass for diesel delivery at site 34 (AJ's) at 2024
Attribution factor for Site Emission offset 16100.00 %Derived
Attribution factor for Site Emission offset 17100.00 %Derived
Attribution factor for Site Emission offset 18100.00 %Derived
Measurement 1160: mass for LCS delivery at site 341.542 tReportedmass for LCS delivery at site 34 (AJ's) at 2024-03
Measurement 1128: El Dorado to Univar Solutoins Tr53.91 kmReportedEl Dorado to Univar Solutoins Truck Route
Attribution factor for Site Emission offset 19100.00 %Derived
Attribution factor for Site Emission offset 20100.00 %Derived
Measurement 1161: mass for LCS delivery at site 341.542 tReportedmass for LCS delivery at site 34 (AJ's) at 2024-03
Attribution factor for Site Emission offset 21100.00 %Derived
Attribution factor for Site Emission offset 22100.00 %Derived
Attribution factor for Site Emission offset 23100.00 %Derived
Attribution factor for Site Emission offset 24100.00 %Derived
Measurement 1133: electricity use at site 1 (advan248.00 kWhReportedelectricity use at site 1 (advantek sw 12) reporte
KS Grid Electricity Emissions emission factor0.46 kgCO₂e/kWhStandard Published ValueKS Grid Electricity Emissions
Attribution factor for Site Emission offset 25100.00 %Derived
Measurement 1136: mass for salt delivery at site 37.739 tReportedmass for salt delivery at site 34 (AJ's) at 2024-0
Measurement 1134: Morton factory to Vaulted to Min112.01 kmReportedMorton factory to Vaulted to Minifinery Facility
Attribution factor for Site Emission offset 26100.00 %Derived
Attribution factor for Embodied Emission offset 201.32 %Derived
Embodied Emission 1: Auger System302 kgReportedembodied emissions for equipment "Auger System" at
Attribution factor for Embodied Emission offset 211.53 %Derived
Embodied Emission 2: Tank Plumbing and Manifold Sy1.311 tReportedembodied emissions for equipment "Tank Plumbing an
Attribution factor for Embodied Emission offset 221.50 %Derived
Embodied Emission 3: Sparge Tank 11.068 tReportedembodied emissions for equipment "Sparge Tank 1" a
Attribution factor for Embodied Emission offset 231.50 %Derived
Embodied Emission 4: Blend Tank A1.068 tReportedembodied emissions for equipment "Blend Tank A" at
Attribution factor for Embodied Emission offset 241.56 %Derived
Embodied Emission 5: MCM Pump 12.496 tReportedembodied emissions for equipment "MCM Pump 1" at s
Attribution factor for Embodied Emission offset 251.56 %Derived
Embodied Emission 6: MCM Pump 22.496 tReportedembodied emissions for equipment "MCM Pump 2" at s
Attribution factor for Embodied Emission offset 261.56 %Derived
Embodied Emission 7: MCM Pump 32.496 tReportedembodied emissions for equipment "MCM Pump 3" at s
Attribution factor for Embodied Emission offset 271.59 %Derived
Embodied Emission 8: Sparging System Air Compresso3.970 tReportedembodied emissions for equipment "Sparging System
Attribution factor for Embodied Emission offset 281.98 %Derived
Embodied Emission 9: Caterpillar XQ200 - Primary F19.970 tReportedembodied emissions for equipment "Caterpillar XQ20
Attribution factor for Embodied Emission offset 290.50 %Derived
Embodied Emission 10: Caterpillar XQ200 -- Chiller19.970 tReportedembodied emissions for equipment "Caterpillar XQ20
Attribution factor for Embodied Emission offset 300.63 %Derived
Embodied Emission 14: Thermal Oxidizer15.490 tReportedembodied emissions for equipment "Thermal Oxidizer
Attribution factor for Embodied Emission offset 310.41 %Derived
Embodied Emission 16: CAT TL1055D32.120 tReportedembodied emissions for equipment "CAT TL1055D" at
Attribution factor for Embodied Emission offset 320.41 %Derived
Embodied Emission 17: CAT 289D318.920 tReportedembodied emissions for equipment "CAT 289D3" at si
Attribution factor for Embodied Emission offset 330.52 %Derived
Embodied Emission 18: Genie S-45 XC24.140 tReportedembodied emissions for equipment "Genie S-45 XC" a
Attribution factor for Embodied Emission offset 343.96 %Derived
Embodied Emission 19: Re-Bar Reinforced Concrete P7.249 tReportedembodied emissions for equipment "Re-Bar Reinforce
Attribution factor for Embodied Emission offset 350.40 %Derived
Embodied Emission 20: LCS Chiller14.160 tReportedembodied emissions for equipment "LCS Chiller" at
Attribution factor for Embodied Emission offset 362.15 %Derived
Embodied Emission 11: Light Tower Generator 11.910 tReportedembodied emissions for equipment "Light Tower Gene
Attribution factor for Embodied Emission offset 372.15 %Derived
Embodied Emission 12: Light Tower Generator 21.910 tReportedembodied emissions for equipment "Light Tower Gene
Attribution factor for Embodied Emission offset 382.15 %Derived
Embodied Emission 13: Light Tower Generator 31.910 tReportedembodied emissions for equipment "Light Tower Gene