Credits issued1,000Y+
8.69 tCO₂e removal by Charm Industrial
Removal details
Supplier
Tonnes removed
8.69 tCO₂e
Sequestration date
06 Apr 2024
Removal method
Calculation view
Data points
Data points (97)
Name | Value | Collection method | Sources |
---|---|---|---|
Attribution factor for Removal 729, Lot 771 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1194: verified mass for lot 771 | 29.316 t | Reported | verified mass for lot 771 |
Measurement 1195: carbon content for removal 729 | 0.431000 | Reported | carbon content for removal 729 |
Removal 729 CO2/C ratio | 3.664141 | Constant | — |
Attribution factor for Removal 729, Lot 770 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1192: verified mass for lot 770 | 11.838 t | Reported | verified mass for lot 770 |
Measurement 1135: Transwood OK to Minifinery to Va | 374.98 km | Reported | Transwood OK to Minifinery to Vaulted |
Tanker Truck Transport Process Emissions emission | 0.08 kgCO₂e/km/t | Standard Published Value | Tanker Truck Transport Process Emissions |
Tanker Truck Transport Embodied Emissions (Deadhea | 0.0477 kgCO₂e/km | Standard Published Value | Tanker Truck Transport Embodied Emissions (Deadhea |
Attribution factor for Removal 729, Lot 769 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1191: verified mass for lot 769 | 22.207 t | Reported | verified mass for lot 769 |
Attribution factor for Removal 729, Lot 748 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1172: verified mass for lot 748 | 8.312 t | Reported | verified mass for lot 748 |
Measurement 1123: AECN to Minifinery Trucking Dist | 3,267.00 km | Reported | AECN to Minifinery Trucking Distance |
Attribution factor for Removal 729, Lot 747 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1171: verified mass for lot 747 | 21.030 t | Reported | verified mass for lot 747 |
Attribution factor for Removal 729, Lot 750 | 100.00 % | Derived | Lot and transfer graph for Removal 727 |
Measurement 1193: LCS used for lot 750 | 1.25 m³ | Reported | LCS used for lot 750 |
Liquid Caustic Soda (LCS) Embodied Emissions emiss | 1,540.65 kg/m³ | Standard Published Value | Liquid Caustic Soda (LCS) Embodied Emissions |
Samples for Injection Batch MRV emission factor | 4 kg | Standard Published Value | Samples for Injection Batch MRV |
Attribution factor for Site Emission offset 27 | 100.00 % | Derived | — |
Measurement 1165: mass for diesel delivery at site | 1.787 t | Reported | mass for diesel delivery at site 34 (AJ's) at 2024 |
Diesel Fuel Combustion emission factor | 3.89 kgCO₂e/kg | Standard Published Value | Diesel Fuel Combustion |
Attribution factor for Site Emission offset 28 | 100.00 % | Derived | — |
Measurement 1130: Minifinery to Security Oil Truck | 4.67 km | Reported | Minifinery to Security Oil Trucking Distance Measu |
Flatbed Truck Transport Process Emissions emission | 0.14 kg/t/mi | Standard Published Value | Flatbed Truck Transport Process Emissions |
Attribution factor for Site Emission offset 29 | 100.00 % | Derived | — |
Flatbed Truck Transport Embodied Emissions emissio | 0.0390 kgCO₂e/km | Standard Published Value | Flatbed truck embodied emissions |
Attribution factor for Site Emission offset 30 | 100.00 % | Derived | — |
Measurement 1166: mass for LCS delivery at site 34 | 1.542 t | Reported | mass for LCS delivery at site 34 (AJ's) at 2024-04 |
Measurement 1128: El Dorado to Univar Solutoins Tr | 53.91 km | Reported | El Dorado to Univar Solutoins Truck Route |
Attribution factor for Site Emission offset 31 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 32 | 100.00 % | Derived | — |
Measurement 1167: mass for LCS delivery at site 34 | 4.627 t | Reported | mass for LCS delivery at site 34 (AJ's) at 2024-04 |
Attribution factor for Site Emission offset 33 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 34 | 100.00 % | Derived | — |
Measurement 1168: mass for salt delivery at site 3 | 13.290 t | Reported | mass for salt delivery at site 34 (AJ's) at 2024-0 |
Measurement 1134: Morton factory to Vaulted to Min | 112.01 km | Reported | Morton factory to Vaulted to Minifinery Facility |
Attribution factor for Site Emission offset 35 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 36 | 100.00 % | Derived | — |
Measurement 1169: mass for salt delivery at site 3 | 8.355 t | Reported | mass for salt delivery at site 34 (AJ's) at 2024-0 |
Attribution factor for Site Emission offset 37 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 38 | 100.00 % | Derived | — |
Measurement 1170: electricity use at site 1 (advan | 251.00 kWh | Reported | electricity use at site 1 (advantek sw 12) reporte |
KS Grid Electricity Emissions emission factor | 0.46 kgCO₂e/kWh | Standard Published Value | KS Grid Electricity Emissions |
Attribution factor for Site Emission offset 39 | 100.00 % | Derived | — |
Measurement 1162: mass for diesel delivery at site | 1.870 t | Reported | mass for diesel delivery at site 34 (AJ's) at 2024 |
Attribution factor for Site Emission offset 40 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 41 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 42 | 100.00 % | Derived | — |
Measurement 1163: mass for diesel delivery at site | 1.311 t | Reported | mass for diesel delivery at site 34 (AJ's) at 2024 |
Attribution factor for Site Emission offset 43 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 44 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 45 | 100.00 % | Derived | — |
Measurement 1164: mass for diesel delivery at site | 483 kg | Reported | mass for diesel delivery at site 34 (AJ's) at 2024 |
Attribution factor for Site Emission offset 46 | 100.00 % | Derived | — |
Attribution factor for Site Emission offset 47 | 100.00 % | Derived | — |
Attribution factor for Embodied Emission offset 39 | 2.06 % | Derived | — |
Embodied Emission 9: Caterpillar XQ200 - Primary F | 19.970 t | Reported | embodied emissions for equipment "Caterpillar XQ20 |
Attribution factor for Embodied Emission offset 40 | 0.51 % | Derived | — |
Embodied Emission 10: Caterpillar XQ200 -- Chiller | 19.970 t | Reported | embodied emissions for equipment "Caterpillar XQ20 |
Attribution factor for Embodied Emission offset 41 | 0.66 % | Derived | — |
Embodied Emission 14: Thermal Oxidizer | 15.490 t | Reported | embodied emissions for equipment "Thermal Oxidizer |
Attribution factor for Embodied Emission offset 42 | 0.43 % | Derived | — |
Embodied Emission 16: CAT TL1055D | 32.120 t | Reported | embodied emissions for equipment "CAT TL1055D" at |
Attribution factor for Embodied Emission offset 43 | 0.43 % | Derived | — |
Embodied Emission 17: CAT 289D3 | 18.920 t | Reported | embodied emissions for equipment "CAT 289D3" at si |
Attribution factor for Embodied Emission offset 44 | 0.53 % | Derived | — |
Embodied Emission 18: Genie S-45 XC | 24.140 t | Reported | embodied emissions for equipment "Genie S-45 XC" a |
Attribution factor for Embodied Emission offset 45 | 4.11 % | Derived | — |
Embodied Emission 19: Re-Bar Reinforced Concrete P | 7.249 t | Reported | embodied emissions for equipment "Re-Bar Reinforce |
Attribution factor for Embodied Emission offset 46 | 0.41 % | Derived | — |
Embodied Emission 20: LCS Chiller | 14.160 t | Reported | embodied emissions for equipment "LCS Chiller" at |
Attribution factor for Embodied Emission offset 47 | 2.25 % | Derived | — |
Embodied Emission 11: Light Tower Generator 1 | 1.910 t | Reported | embodied emissions for equipment "Light Tower Gene |
Attribution factor for Embodied Emission offset 48 | 2.25 % | Derived | — |
Embodied Emission 12: Light Tower Generator 2 | 1.910 t | Reported | embodied emissions for equipment "Light Tower Gene |
Attribution factor for Embodied Emission offset 49 | 2.25 % | Derived | — |
Embodied Emission 13: Light Tower Generator 3 | 1.910 t | Reported | embodied emissions for equipment "Light Tower Gene |
Attribution factor for Embodied Emission offset 50 | 1.66 % | Derived | — |
Embodied Emission 1: Auger System | 302 kg | Reported | embodied emissions for equipment "Auger System" at |
Attribution factor for Embodied Emission offset 51 | 1.68 % | Derived | — |
Embodied Emission 2: Tank Plumbing and Manifold Sy | 1.311 t | Reported | embodied emissions for equipment "Tank Plumbing an |
Attribution factor for Embodied Emission offset 52 | 1.69 % | Derived | — |
Embodied Emission 3: Sparge Tank 1 | 1.068 t | Reported | embodied emissions for equipment "Sparge Tank 1" a |
Attribution factor for Embodied Emission offset 53 | 1.69 % | Derived | — |
Embodied Emission 4: Blend Tank A | 1.068 t | Reported | embodied emissions for equipment "Blend Tank A" at |
Attribution factor for Embodied Emission offset 54 | 1.64 % | Derived | — |
Embodied Emission 5: MCM Pump 1 | 2.496 t | Reported | embodied emissions for equipment "MCM Pump 1" at s |
Attribution factor for Embodied Emission offset 55 | 1.64 % | Derived | — |
Embodied Emission 6: MCM Pump 2 | 2.496 t | Reported | embodied emissions for equipment "MCM Pump 2" at s |
Attribution factor for Embodied Emission offset 56 | 1.64 % | Derived | — |
Embodied Emission 7: MCM Pump 3 | 2.496 t | Reported | embodied emissions for equipment "MCM Pump 3" at s |
Attribution factor for Embodied Emission offset 57 | 1.64 % | Derived | — |
Embodied Emission 8: Sparging System Air Compresso | 3.970 t | Reported | embodied emissions for equipment "Sparging System |
AECN Pyrolysis Process Emissions (Stack-Inclusive) | 89.40 kgCO₂e/t | Standard Published Value | AECN Pyrolysis Process Emissions (Stack-Inclusive) |
AECN Pyrolysis Embodied Emissions emission factor | 21.16 kgCO₂e/t | Standard Published Value | AECN Pyrolysis Embodied Emissions |